- 5 -
Spares Operation - R.Kurzke 02/02
599 513 616
EN
Interference Filter
The interference filter is
connected in the terminal
board parallel to the mains
feed.
Pressure Switch
The pressure switch controls the water level.
Without water, contact is opened.
fN
Switch point with level
47 mm Ws
Reset point with level
10 mm Ws
Overfill
3 l
The pressure switch is not adjustable.
Flow Heater
The flow heater heats the water to the required temperature.
During the wash cycle, water is contantly passing through the
flow heater.
Power output
1100 W (1000 W, UK)
Resistor
49
W (53 W,
UK)
Protector
98 °C ± 5 K
Thermal fuse
206 °C