6. Leakage Protection
The anti-flood switch in the base tray will activate the drain pump and drain the water from the tub
in the event of an internal leakage.
If the float switch is activated, all electric components are switched off except the drain pump.
Overflow protection
The filling phase fills up to the level, monitored by a pressure monitor. If the pressure monitor does
not switch in, this filling phase is generally limited electronically to 2 minutes.
If the pressure monitor has not switched in by then, the electronics jump to the error mode "shut off
tap", and the program is stopped.
If the pressure switch switches back during the cycle, a maximum of 10 sec. further filling is
possible. If the pressure monitor has not switched in by then, the electronics jump to the error
mode "shut off tap", and the program is stopped.
Safety level
If the safety level is reached by over-fillling more than approx. 3 litres, floater switch starts the drain
pump.
Safety level
Summary of Contents for Favorit CE
Page 1: ...Favorit CE Dishwasher Instruction book Aus Erfahrung Gut ...
Page 28: ...822 61 10 33 ...
Page 38: ... 10 Spares Operation R Kurzke 02 02 599 513 616 EN 4 Position of components ...
Page 39: ... 11 Spares Operation R Kurzke 02 02 599 513 616 EN 5 Water Course Scheme ...
Page 57: ... 29 Spares Operation R Kurzke 02 02 599 513 616 EN ...
Page 58: ... 30 Spares Operation R Kurzke 02 02 599 513 616 EN ...
Page 60: ...N9113380102_1 ...
Page 61: ...N9113380102_2 ...
Page 76: ...Explosionszeichnungs Nr N 8731 A06 Number of picture ...
Page 77: ...Explosionszeichnungs Nr N 8731 A07 Number of picture ...
Page 78: ...Explosionszeichnungs Nr N 8731 A08 Number of picture ...
Page 79: ...Explosionszeichnungs Nr N 8731 A09 Number of picture ...
Page 80: ...Explosionszeichnungs Nr N 59112003232 Number of picture ...