What to do if …
14
What to do if
…
If you are unable to remedy the problem by following the above sugges
tions, please contact your dealer or the Customer Care Department.
1
Warning!
Repairs to the appliance are only to be carried out by qualified service
engineers. Considerable danger to the user may result from improper repairs.
3
If the appliance has been wrongly operated, the visit from the customer service
technician or dealer may not take place free of charge, even during the warranty
period.
Problem
Possible cause
Remedy
The appliance cannot be
switched on or is not operat
ing
More than 10 seconds have
passed since the appliance was
switched on
Switch appliance on again
Several sensor fields were
touched at the same time
Only touch one sensor field
The sensor fields are partly
covered by a damp cloth or
with liquid
Remove the cloth or the liquid.
Switch appliance on again
Electronics fault
Disconnect appliance from the
electrical supply for a few
minutes. (Take the fuse out of
the house’s wiring system.)
If the appliance still does not
operate after switching on
again, call the Customer Care
Department
Fuses keep blowing
Too many electrical applianc
es are connected
Switch off electrical applianc
es
The fan is switched off, but the
down draught extractor is
raised
There was a power cut during
operation
Switch on down draught ex
tractor and touch
e
is displayed
Filter sensor has responded.
Clean filter and reset filter
sensor (see section “Cleaning
and Care”)
Down draught extractor has
switched off automatically
and cannot be switched on
again
Vertical adjustment of the
down draught extractor has
become jammed
Disconnect appliance from the
electrical supply for a few
minutes. (Take the fuse out of
the house’s wiring system.)
If the appliance still does not
operate after switching on
again, call the Customer Care
Department
Summary of Contents for FM2500DD-A
Page 1: ...FM2500DD A User manual Down draught extractor ...
Page 19: ...19 Assembly Assembly ...
Page 20: ...Assembly 20 ...
Page 21: ...21 Assembly ...
Page 22: ...Assembly 22 ...
Page 27: ...27 Rating Plate 941 177 540 230 240 V 0 31 kW FDD 180 FM2500DD A 50 Hz AEG ELECTROLUX ...