8.4
Adjustment of minimum
level
To adjust the minimum level of the
burners:
1.
Light the burner.
2.
Turn the knob on the minimum
position.
3.
Remove the knob.
4.
With a thin screwdriver, adjust the
bypass screw position (A).
A
5.
If you change:
• from natural gas G20 20 mbar to
liquid gas, fully tighten the bypass
screw in.
• from liquid gas to natural gas G20
20 mbar, undo the bypass screw
approximately 1/4 of a turn.
WARNING!
Make sure the flame does
not go out when you quickly
turn the knob from the
maximum position to the
minimum position.
8.5
Electrical connection
• Make sure that the rated voltage and
type of power on the rating plate
agree with the voltage and the power
of the local power supply.
• This appliance is supplied with a
mains cable and a plug.
• Always use a correctly installed
shockproof socket.
• Make sure that there is an access to
the mains plug after the installation.
• Do not pull the mains cable to
disconnect the appliance. Always pull
the mains plug.
• There is a risk of fire when the
appliance is in connection with an
extension cable, an adapter or a
multiple connection. Make sure that
the ground connection agrees with
the standards and regulations.
• Do not let the power cable to heat up
to a temperature higher than 90° C.
Make sure that you connect
the blue neutral cable to the
terminal with a letter "N" on
it. Connect the brown (or
black) phase cable to the
terminal which has a letter
"L". Keep the phase cable
connected at all times.
8.6
Connection cable
To replace the connection cable use only
the special cable or its equivalent. The
cable type is: H05V2V2-FT90.
Make sure that the cable section is
applicable to the voltage and the
working temperature. The yellow / green
earth wire must be approximately 2 cm
longer than the brown (or black) phase
wire.
ENGLISH
45