Possibilities for insertion
Kitchen unit with door
The panel installed below the hob must be easy to remove and let an easy access in case a
technical assistance intervention is necessary.
min 20 mm
(max 150 mm)
30 mm
60 mm
b
a
a) Removable panel
b) Space for connections
Kitchen unit with oven
The hob recess dimensions must obey the indication and the kitchen unit must be equipped
with vents to let a continuous supply of air. The electrical connection of the hob and the
oven must be installed separately for safety reasons and to let easy remove oven from the
unit.
50 cm2
360 cm2
180 cm2
120 cm2
PRODUCT DESCRIPTION
Cooking surface layout
1
2
3
4
180
mm
145
mm
1
Rear cooking zone 2000 W
2
Front cooking zone 1500 W
3
Power indicator
4
Control knobs
20