Problem
Possible cause
Remedy
comes on.
There is an error in the hob
because a cookware boils
dry. Automatic Switch Off
and the overheating protec-
tion for the zones operate.
Deactivate the hob. Remove
the hot cookware. After ap-
proximately 30 seconds, acti-
vate the zone again. If the
cookware was the problem,
the error message goes out.
Residual heat indicator can
stay on. Let the cookware
become sufficiently cool.
Check if your cookware is
compatible with the hob.
Refer to “Hints and tips”
chapter.
7.2
If you cannot find a
solution...
If you cannot find a solution to the
problem yourself, contact your dealer or
an Authorised Service Centre. Give the
data from the rating plate. Give also
three digit letter code for the glass
ceramic (it is in the corner of the glass
surface) and an error message that
comes on. Make sure, you operated the
hob correctly. If not the servicing by a
service technician or dealer will not be
free of charge, also during the warranty
period. The instructions about the
Service Centre and conditions of
guarantee are in the guarantee booklet.
8.
INSTALLATION
WARNING!
Refer to Safety chapters.
8.1
Before the installation
Before you install the hob, write down
the information bellow from the rating
plate. The rating plate is on the bottom
of the hob.
Serial number ...........................
8.2
Built-in hobs
Only use the built-in hobs after you
assemble the hob into correct built-in
units and work surfaces that align to the
standards.
8.3
Connection cable
• The hob is supplied with the
connection cable.
• Replace the damaged mains cable
only with the spare parts cable. Speak
to your local Authorised Service
Center.
WARNING!
All electrical connections
must be made by a qualified
electrician.
CAUTION!
Do not drill or solder the
wire ends. This is strictly
forbidden!
CAUTION!
Do not connect the cable
without cable end sleeve.
Two-phase connection
1.
Remove the cable end sleeve from
black and brown wires.
2.
Remove an insulation of the brown
and black cable ends.
3.
Apply a new wire end sleeve of 1.5
mm² on each cable end. (special tool
required).
www.aeg.com