• Disconnect the appliance from the mains
supply.
• Cut off the mains electrical cable close to
the appliance and dispose of it.
3. INSTALLATION
WARNING!
Refer to Safety chapters.
3.1 Before the installation
Before you install the hob, write down the
information below from the rating plate. The
rating plate is on the bottom of the hob.
Serial number ...........................
3.2 Built-in hobs
Only use the built-in hobs after you assemble
the hob into correct built-in units and work
surfaces that align to the standards.
3.3 Connection cable
• The hob is supplied with a connection
cable.
• To replace the damaged mains cable, use
the cable type: H05V2V2-F which
withstands a temperature of 90 °C or
higher. The single wire must have a
diameter of minimum 1,5 mm². Speak to
your local Service Centre. The connection
cable may only be replaced by a qualified
electrician.
WARNING!
All electrical connections must
be made by a qualified
electrician.
CAUTION!
Connections via contact plugs
are forbidden.
CAUTION!
Do not drill or solder the wire
ends. It is forbidden.
CAUTION!
Do not connect the cable without
cable end sleeve.
One-phase connection
1. Remove the cable end sleeve from black
and brown wires.
2. Remove an insulation of the brown and
black cable ends.
3. Merge the black and brown cable ends.
4. Apply a new wire end sleeve on the
common cable end (special tool
required).
Cable cross section 2 x 1,5 mm²
N
L1
N
L
220-240 V~
400V 2~N
L2
One-phase connection: 220 - 240 V~
Two-phase connection: 400 V 2 ~ N
Green - yellow
Green - yellow
N
Blue and blue
Blue and blue
N
L
Black and brown
Black
L1
Brown
L2
ENGLISH
51