• Turn the heater and replace the screw in position “2” (see pictures 7c and 7d);
• Change the switch cord pattern. The cord must always exit from the bottom
of the control unit (see pictures 7a and 7d).
3) Connection to the mains electricity supply
• The appliance may only be connected to a 1/N/PE 230V AC 50 Hz supply with
a three core lead ( phase, neutral and earth wires).
• Make sure that the supply socket has 3 conductors : L , N and earth contact
• The safety precautions usual in the country of use and the regulations of the
local electricity supply are to be observed. The appliance is fitted in the factory
with an all – pole switch providing a contact break distance of
≥
3 mm.
• DO NOT pivot the product upwards;
• BE SURE that the fixing screw of the front cover is on the top of the product as
shown in picture 4.
4) Operation
• Pulling the switch the product gets in function. You can see from the front
viewing window the following symbols
Product rating
0
I
230V 1200W
OFF
600W
• It is possible to swivel the housing downwards up to a maximum of 45° (pic
-
ture 10) Before doing this the appliance must be in 0 position (OFF) and must
have cooled down for at least 15 minutes.
5) Maintenance
● This product does not require any special maintenance.
● Clean the product with a dry cloth once every 6 months.
● If the product requires repairing, contact an authorised technical
service centre.
● In case the power cord is damaged and you have to replace it,
please take the unit to an authorized after sales service in order to
avoid any risk of danger. In this case a 3x0,75mm2 supply power
cord H05RR-F type is to be used.
6) Legal notice
Environment and recycling
Please help us to protect the environment by disposing of the packaging in ac
-
cordance with the national regulations for waste processing.
Recycling of obsolete appliances
Appliances with this label must not be disposed off with the general waste. They
must be collected separately and disposed off according to local regulations.
11