2.
Close the water tap.
3.
Put the two ends of the inlet hose in
a container and let the water flow out
of the hose.
4.
Empty the drain pump. Refer to the
emergency drain procedure.
5.
When the drain pump is empty,
install the inlet hose again.
WARNING!
Make sure that the
temperature is higher than 0
°C before you use the
appliance again.
The manufacturer is not
responsible for damages
caused by low temperatures.
13.
TROUBLESHOOTING
WARNING!
Refer to Safety chapters.
13.1
Introduction
The appliance does not start or it stops
during operation.
First try to find a solution to the problem
(refer to the table). If the problem
persists, contact the Authorised Service
Centre.
In case of major problems, the acoustic
signals operate, the display shows an
alarm code and the
Start/Pauze
button
may flash continuously:
•
- The appliance does not fill with
water properly.
•
- The appliance does not drain
the water.
•
- The appliance door is open or
not closed correctly. Please check the
door!
If the appliance is
overloaded, remove
some items from the
drum and/or keep
pressed the door while
touching the Start/Pauze
button until the indicator
stops flashing (see
the picture below).
•
- The mains supply is unstable.
Wait until the mains supply is stable.
•
- No communication between
electronic elements of the appliance.
Switch it off and switch on again.
•
- The anti-flood device is on.
Disconnect the appliance and close
the water tap. Contact the Authorised
Service Centre.
WARNING!
Deactivate the appliance
before carrying out any
check.
13.2
Possible failures
Problem
Possible solution
The programme does
not start.
Make sure that the mains plug is connected to the mains sock-
et.
www.aeg.com
32