14th digit
15th digit
13th digit
Factory Installed prevision to mount
a Key lock on the breakers
For Profalux Key lock
P
For Ronis Key lock
R
For Large Castell type Key lock
C
Pushbutton Padlock Device
L
Large Castell Key Interlock &
Push Button Pad. Device
1
Ronis Key Interlock and Push
Button Padlock Device
3
Profalux Key Interlock & Push
Button Pad. Device
4
No prevision for Key lock
X
Factory Installed prevision to mount a Cable
interlock between breakers
Mechanical Interlock -Type A or D supply
1
Mechanical Interlock Type B all
2
Mechanical Interlock Type C all
3
Mechanical Interlock Type D tie only
4
No prevision for Breaker interlock
X
Factory Installed prevision to mount a Cable
interlock between breakers.
X
2
X
A
Auxiliary Switches & Confi guration
Type
Code to be added
(1)
3NO+3NC (Power Rated)
(1)
2
A
B
C
D
E
F
G
H
S
T
4NO+4NC (Power Rated)
3
8NO+8NC (Power Rated)
4
J
K
L
M
N
P
Q
R
U
V
3NO/3NC (Power Rated) + 2NO/2NC (Signal)
6
4NO/4NC (Power Rated) + 4NO/4NC Signal)
8
No other contacts installed
Coil Signaling Contact P
ower (1 NO on Secondary
Disconnect) - Close Coil or command close coil
Coil Signaling Contact High Fidelity thr
ough Trip
Unit - Close Coil or command close coil
Coil Signaling Contact P
ower (1 NO on Secondary
Disconnect) - 1st Shunt
Coil Signaling Contact High Fidelity thr
ough Trip
Unit - 1st Shunt
Coil Signaling Contact P
ower (1 NO on Secondary
Disconnect) - 1st UVR
Coil Signaling Contact High Fidelity thr
ough Trip
Unit - 1st UVR
Coil Signaling Contact P
ower (1 NO on Secondary
Disconnect) - 2nd ST or 2nd UVR
Coil Signaling Contact High Fidelity thr
ough Trip
Unit - 2nd ST or 2nd UVR
C
oi
l S
ig
na
lin
g
C
on
ta
ct
Po
w
er
(1
N
O
on
Se
co
nd
ary
D
is
co
nn
ec
t) - A
ll i
ns
ta
lle
d d
ev
ic
es C
C
/C
CC
, S
T, o
r U
VR
)
Coil Signaling Contact High Fidelity (1 NO -Thr
ough
Trip Unit) - All installed devices. C
C/C
CC, ST
, or UVR)
Designation
Code to be added
(1)
Bell Alarm 1 NO Power rated
A
D
E
F
Bell Alarm 1 NO Signal rated
N
P
R
S
Mechanical Operations Counter
B
K
L
M
Bell Alarm 1NO power rated & Mechanical Operations ctr.
C
G
H
J
Bell Alarm 1NO signal rated & Mechanical Operations ctr.
T
U
V
Y
Ready to Close contact 1 NO Power Rated on Secondary terminals
1
Ready to Close contact 1 NO Signal Rated on Secondary terminals
2
Ready to Close contact 1 NO Signal Rated connected Through Trip Unit
3
Ready to Close contact 1 NC Power Rated on Secondary terminals
4
Ready to Close contact 1 NC Signal Rated on Secondary terminals
5
Ready to Close contact 1 NC Signal Rated connected Through Trip Unit
6
None
X
No other contacts installed
Ready to C.ose contact 1 NO P
ower
Rated on Secondary terminals
Ready to C.ose contact 1 NO SIgnal
Rated on Secondary terminals
Ready to C.ose contact 1 NO SIgnal
Rated connected Thr
ough Trip Unit
12th digit
Envelope 1/2/3 only
Envelope T only
(1) Each standard breaker or Isolator is normally supplied with 3 NO+3 NC Aux. contacts.
6.1-02
English
Global Catalogue number structure - Breaker
-- Codes built in the indicated manner can be used as an alternative ordering method
-- The breaker and its operation mode (Manual or Electrical)
LOCKS
ME10 Breaker
INTRO
BREAKER
ACCESSORIES
TESTS
APPENDIX
TRIP UNIT
CA
TAL
OGUE
DIMENSION
SERVICE
C
ONTENT