INTR
O
SPECIFICA
TION
INST
ALL
A
TION
OPER
A
TION
TRIP UNIT
LOCKS
BREAKER ME10
INTRO
BREAKER
ACCESSORIES
TESTS
APPENDIX
1.3-06
20
65
30
25
R6.5
A 3x M10x60 - 8.8
B 6x M10
C 6x M10
D 3x M10 - 8.8
1
38-42 Nm
2x M10 x 60 -8.8
B 4x M10
C 4x M10
D 2x M10 -8.8
A
1)
2)
3)
5)
4)
50
29
25
17
R6.5
Ø 13
15
3
4
.5
3
1
50
13
17
65
27,5
18,75
15,5
65
22
22
Ø
12
11
17
65
30
25
R6
.5
1
7
S 400-1600A
N&H 400-1600A
S 400-1600A
6)
15
30
25
17.5
R6.5
58
S 2000A
N&H 400-2000A
2 holes
Ø 12
58
15
31
1
7
8
7)
2x M10 x 60 -8.8
B 4x M10
C 4x M10
D 2x M10 -8.8
A
8)
9)
65
22
22
Ø
12
11
17
A 3x M10x60 - 8.8
B 6x M10
C 6x M10
D 3x M10 - 8.8
400-2000A
400-2000A
2000A
400-1600A
2000A
Fixed patt
ern
F
est
einbaut
echnik
Esecuzione fissa
Draw-out patt
ern
Einfahr
technik
Esecuzione estraibile
13
25 25 25
4 holes
Ø 13
1
4
25
25
25
13
13
15
90
4 holes Ø 13
A 4x M12x60/90 - 8.8
B 8x M12
C 8x M12
D 4x M12 - 8.8
2
50-60 Nm
1)
3)
2)
5)
400-3200A
4)
6)
95
10
25 25 25
Ø 13
17
12.5
25 25 25
Ø 13
100
17
100
12.5
25 25 25
Ø 12
20
58
4 holes
Ø 13
13
12
2
5
2
5
2
5
1
3
3200 & 4000A
4000A
Enhanced Thermal
rated version
400 & 4000A
400-4000A
400-4000A
Fixed patt
ern
F
est
einbaut
echnik
Esecuzione fissa
Draw-out patt
ern
Einfahr
technik
Esecuzione estraibile
A 4x M12x60/90 - 8.8
B 8x M12
C 8x M12
D 4x M12 - 8.8
3
50-60 Nm
1)
3)
2)
4000-5000A
4000 & 6400A
88
30 30
14
17
Ø 13
A 3x M12x60/80 - 8.8
B 6x M12
C 6x M12
D 3x M12 - 8.8
18
120
25
25
25
Ø 13
4000-5000A
4000-6400A
51
18
Ø 13
25
25
25
3)
51
18
Ø 13
25
25
25
Fixed patt
ern
F
est
einbaut
echnik
Esecuzione fissa
Draw-out patt
ern
Einfahr
technik
Esecuzione estraibile
25.0
22.0
R5.5
TYP
R5.5
TYP
45.0
17.0
25.0
22.0
22
25
20
R5.5
TYP
17
25
44
22
35
25
22
R5.5
TYP
17
44.0
R5.5
TYP
44
22
25
17
Fixed patt
ern
F
est
einbaut
echnik
Esecuzione fissa
T
38-42 Nm
Draw-out patt
ern
Einfahr
technik
Esecuzione estraibile
2x M10 x 60 -8.8
B 4x M10
C 4x M10
D 2x M10 -8.8
A
1)
2)
3)
4)
5)
6)
R&K
R&K 400-1600A
R&K
R&K
R&K 400-1600A
R&K 400-1600A
Horizontal
Vertical
Front
Rear | Rückseitig | Posteriore
Connection modes & application
Anschlussarten & Ausführung
Modalità di connessione e applicazione
A
B
C
D
Envelope
Baugröße
Taglia
1) Fixed pattern R&K type 400-1600A Rear
Horizontal
2) Fixed pattern R&K type 400-1600A Rear
Vertical
3) Fixed pattern R&K type 400-1600A Front
4) Drawout pattern R&K type 400-1600A
Rear Horizontal or Vertical
5) Drawout pattern R&K type 400-1600A
Front
6) Drawout pattern R&K type 400-1600A
Rear Horizontal
1) Fixed pattern S type 400-1600A Rear
Horizontal
2) Fixed pattern 400-2000A Rear Vertical
3) Fixed pattern N&H type 400-1600A Rear
Horizontal
4) Fixed pattern 2000A Rear Horizontal
5) Fixed pattern 400-2000A Front
6) Drawout pattern S type 400-1600A Rear
Horizontal or Vertical
7) Drawout pattern S type 2000A, N&H 400-
2000A
8) Drawout pattern 400-1600A Front
9) Drawout pattern 2000A Front
1) Fixed pattern 400-4000A Rear Horizontal
or Vertical2) Fixed pattern 400-4000A
Front
3) Drawout pattern 400-3200A Rear
Horizontal or Vertical
4) Drawout pattern 400-4000A Front
5) Drawout pattern 4000A Rear Vertical
ONLY
6) Drawout pattern -enhanced thermal
rated version 3200A & 4000A Rear Vertical
ONLY
1) Fixed pattern 4000-5000A Rear Horizontal
2) Fixed pattern 4000-6400A Rear Vertical
3) Drawout pattern 4000-5000A Rear Horizontal or 4000-6400A Vertical
(1)
(1) The envelope 3 draw-out pattern construction has two connection
pads per connection point.
A
B
C
D
A
B
C
D