41
A malfunction may be caused by only a minor fault that you can rec-
tify yourself using the following instructions.
Please check whether the pilot lamps come on, the refrigerating unit
operates, and the internal temperature is being maintained.
Do not perform any other work on the appliance if the following infor-
mation does not provide assistance in your specific case.
Warning!
Repairs to refrigerators/freezers may only be performed by
qualified service engineers. Improper repairs can give rise to significant
hazards for the user. If your appliance needs repairing, please contact
your specialist dealer or our Customer Service.
If the freezing mechanism has stopped working, the reserve in the col-
daccumulator and in the deep-frozen food itself, if the freezer is full,
will be sufficient for about 27 hours, or about 18 hours if there is no
cold accumulator.
Malfunction
Appliance does not work,
no pilot light is illumina-
ted.
Possible Cause
Appliance is not switched
on.
Mains plug is not plugged
in or is loose
Fuse has blown or is defec-
tive
Socket is defective
Mains malfunctions are to
be corrected by an electri-
cian.
Remedy
Switch on the appliance.
Insert mains plug.
Check fuse, replace if
necessary.
Green light does not light
up, yellow light lights up
when the fast freeze func-
tion is activated.
Green light faulty.
Yellow light does not light
up when the fast freeze
function is activated,
appliance is on
Yellow light faulty.
Temperature is set too
cold.
Please inform your custo-
mer service.
Turn the temperature
regulator to a warmer set-
ting temporarily.
Please inform your custo-
mer service.
Appliance cools too much.