Safety warnings

for the user

• Always cover lighted elements, to prevent excess heat from

damaging the appliance.  In the case of oil, gas and coal fired
cookers it is essential to avoid open flames.

• Also, when frying, keep the deep frying pan on the cooker top/cooker

under careful control.

• The hot oil in the frying pan might ignite due to overheating.
• The risk of self-ignition increases when the oil being used is dirty.
• It is extremely important to note that overheating can cause a fire.
• Never carry out any flambé cooking under the hood.
• Always disconnect the unit from the power supply before

carrying out any work on the hood, including replacing the
light bulb
 (take the cartridge fuse out of the fuse holder or switch off
the automatic circuit breaker).

• It is very important to clean the hood and replace the filter at

the recommended intervals. Failure to do so could cause
grease deposits to build up, resulting in a fire hazard.

for the installer

• When used as an extractor unit, the hood must be fitted with a

150mm diameter hose.

• Should there already be a pipe of diameter 125 mm that ducts to the

outside through the walls or roof, it is possible to use the 150/125
mm reduction flange provided. In this case the hood will be slightly
more noisy.

• When installing the hood, make sure you respect the following

minimum distance from the top edge of the cooking hob/ring
surfaces:
electric cookers

600 mm

gas cookers

650 mm

coal and oil cookers

700 mm min.

• The national Standard on fuel-burning systems specifies a maximum

depression of 0.04 bar in such rooms.

• The air outlet must not be connected to chimney flues or combustion

gas ducts. The air outlet must under no circumstances be connected
to ventilation ducts for rooms in which fuel-burning appliances are
installed.

Summary of Contents for protect d. 3000

Page 1: ...D 3010 D Dunstabzugshaube Afzuigkap Hotte aspirante Cooker Hood Montage und Gebrauchsanweisung Installatie en gebruiksaanwijzing Notice d utilisation et d installation Operating and Installation Instructions ...

Page 2: ... for charcoal filter E 68 Resetting the saturation indicator 68 Maintenance and care 69 Metal grease filter 69 Open the metal grease filter 69 Charcoal filter 70 Changing the light bulb 71 Cleaning 72 Special accessories 72 Technical assistance service 72 Guarantee conditions 73 Technic Details 74 Mounting accessories included 74 Electrical connection 74 Safety warnings for the electrician 74 Wall...

Page 3: ...n the hood and replace the filter at the recommended intervals Failure to do so could cause grease deposits to build up resulting in a fire hazard for the installer When used as an extractor unit the hood must be fitted with a 150mm diameter hose Should there already be a pipe of diameter 125 mm that ducts to the outside through the walls or roof it is possible to use the 150 125 mm reduction flan...

Page 4: ...rge to avoid the possibility of a depression being created during operation of the hood If you have any doubts contact the relevant controlling authority or building inspector s office Since the rule for rooms with fuel burning appliances is outlet hole of the same size as the ventilation hole a hole of 500 600 cm2 which is to say a larger hole could reduce the performance of the extractor hood If...

Page 5: ... use the 150 125 mm reduction flange provided In this case the hood will be slightly more noisy Filter Version The air is filtered through an charcoal filter and returned to the kitchen through the top grill of the outlet pipe You will need an original AEG KF20 charcoal filter for the filtering function See Special Accessories Assemble the deflector 3 parts the three parts must be fixed with 2 scr...

Page 6: ...dication of the grease saturation for the filter flashing indicator E Indicates speed 3 LED and indication of the charcoal saturation for the filter flashing indicator F Indicates Intensive speed LED G Intensive speed on off The Intensive speed runs for 5 minutes If the hood is on when the Intensive speed is activated the hood reverts to previous speed after 5 minutes If the hood is off when the I...

Page 7: ... off the saturation detection depress and hold the B and G buttons for 3 seconds until the LED indicator for the active carbon filter is flashing Led Indicator for grease filter D The LED indicator for the grease filter will flash when it requires cleaning Follow the maintenance instructions Led indicator for charcoal filter E The LED indicator for the charcoal filter illuminates when the filter r...

Page 8: ...hen extract the filter pulling downwards Fig 4 Hand washing Soak grease filters for about one hour in hot water with a grease loosening cleaner then rinse off thoroughly with hot water Repeat the process if necessary Refit the grease filters when they are dry Dishwasher machine Place grease filters in dish washer Select most powerful washing programme and highest temperature at least 65 C Repeat t...

Page 9: ...at no food parts gets stuck on the filter and later causes bad odours To reactivate the charcoal the filter should be dried in an oven for 10 minutes with a temperature of maximum 100º C After approximately three years of use the charcoal filter should be replaced with a new as the odour reduction capacity will be reduced Mounting Remove the frame i which supports the filter h by turning 90 the tw...

Page 10: ...the motor or any fire damage linked to inappropriate maintenance or failure to observe the above safety recommendations Changing the light bulb Disconnect the cooker hood from the main supply Remove the lamp cover use a screw driver as a lever Fig 6 Replace the old bulb with a new one of the same type Remount the lamp cover If the light does not come on make sure the bulb has been inserted in corr...

Page 11: ...e to do so will cause grease deposits to build up that could constitute a fire hazard Special accessories Charcoal filter KF20 942 120 600 Technical assistance service You are welcome to telephone our technical assistance service see list of technical assistance centres whenever you need information or in the unlikely event of a fault When calling please be ready to specify 1 The model code number...

Page 12: ...als 5 Repairs carried out under guarantee do not extend the guarantee period for the appliance Parts removed during guarantee repairs become the property of AEG 6 The purchaser s statutory rights are not affected by this guarantee European Guarantee IfyoushouldmovetoanothercountrywithinEuropethenyourguaranteemoveswithyoutoyour newhomesubjecttothefollowingqualifications The guarantee starts from th...

Page 13: ...creen to the cooker hood 2 metal screws 3 x 9 to affix the frame to the cooker hood 1 allen spanner for TORX screws Electrical connection Safety warnings for the electrician Before connecting the appliance to the power supply check that the volt age indicated on the rating plate corresponds to the mains power supply available Appliances fitted with a plug can be connected to any standard power soc...

Page 14: ...hat the side with slots is up see also A B C sequence on on Fig 7 Assembling the chimney flue support bracket 3 parts The three parts should be fixed with 4 screws the support extension is adjustable and should correspond to the internal width of the telescopic chimney flue Assembling the deflector 3 parts only for filter version The three parts should be fixed with 2 screws the deflector extensio...

Page 15: ...In case the hood is to be used in filter version mount the deflector F on the chimney support with four screws 2 9x6 5 and fit an exhausting pipe 15 to connect deflector to the outlet hole D of the hood In case the hood is to be used in exhausting version then the deflector must not be mounted and fit an exhausting pipe 15 to connect outlet hole D of the hood to the outside Make electrical connect...

Page 16: ...77 Fig 8 20b 12 19b 19b 7 7 4 5 6 8 9 13 13 14 15 19a 9 8 16 8 9 10 11 20a 20a 20b 19a 17 18 18 18 F G H 1 2 3 D Model 3010D ...

Page 17: ...78 ...

Page 18: ...79 ...

Page 19: ...AEG Hausgeräte GmbH Postfach 1036 D 90327 Nürnberg http www aeg hausgeraete de Copyright by AEG LI1M7C Ed 07 02 ...

Reviews: