20 

Trouble shooting 

Error 

Cause 

Remedy 

Yellow LED is 
lighting, but audible 
alarm is heard 
intermittently. 

UPS not connected 
properly to the mains. 

Connect the UPS 
according to the 
installation guide.

 

UPS is functioning 
but audible alarm is 
heard periodically. 

UPS overload. 

Verify that the load 
matches the UPS 
capacity specified in the 
spec.

 

Software not installed 
well. 

Check the setting of the 
software. 

Communication 
lost between UPS 
and Computer. 

Cable is not properly 
connected. 

Check if the RS232 or 
USB cable is firmly 
connected to the 
COM1/COM“ or USB of 
the computer and confirm 
the setting.  

Red LED is 
lighting, alarm is 
heard continuously. 

Hardware error in the 
UPS. 

Contact dealer! 

 

If any abnormal situations occur that are not listed above, 
please call the service centre immediately or contact our 
hotline (see page 4) 

 

Summary of Contents for Protect Home

Page 1: ...OPERATING INSTRUCTIONS UPS PROTECT HOME PROTECT HOME ...

Page 2: ...AEG UPS PROTECT HOME from AEG Power Solutions Safety information and operating instructions are included in this manual To ensure correct use of the UPS please read this manual thoroughly before operating it Save this manual properly ...

Page 3: ... the unit Validity These operating instructions comply with the current technical specifications of PROTECT HOME at the time of publication The contents do not constitute a subject matter of the contract but serve for information purposes only Warranty and Liability We reserve the right to alter any specifications given in these operating instructions especially with regard to technical data and o...

Page 4: ...ithout any internal manipulation of the unit Maintenance and repair work may only be performed by trained and qualified personnel Hotline If you still have questions after having read these operating instructions please contact your dealer or our Hotline Phone 49 0 180 5 234 787 Fax 49 0 180 5 234 789 Internet www AEGppartnernet com Copyright No part of these operating instructions may be transmit...

Page 5: ...1 1 Certification 5 ...

Page 6: ... in these operating instructions to identify dangers and important information Danger Identifies risk of fatal injury to the operator Warning Identifies risk of injury and risk of damage to the unit and parts of the unit i Information Useful and important hints for the operation of the UPS 2 2 Safety Instructions for PROTECT HOME This chapter contains important instructions for the UPS PROTECT HOM...

Page 7: ...the battery voltage of PROTECT HOME is exhausted or when the UPS is not working in its normal mode Observe the following safety instructions to ensure permanent operational safety of and safe work with the UPS Do not dismantle the UPS The UPS does not contain any parts which require regular maintenance Bear in mind that the warranty will be invalidated if the unit is opened Do not install the unit...

Page 8: ...tric shocks Even after the mains voltage has been disconnected the components within the UPS remain connected to the battery and can thus cause electric shocks It is therefore imperative to disconnect the battery circuit before carrying out any maintenance or repair work If it is necessary to replace the battery or carry out maintenance work this must be done by or under the supervision of a perso...

Page 9: ...re take the following safety precautions when working with batteries Take off watches rings and other metallic objects Always use tools with insulated handles For personal safety reasons never switch on the main switch when the mains connector of PROTECT HOME is disconnected 9 ...

Page 10: ...s i e if PROTECT HOME is supplied with mains voltage the battery charger will ensure that the battery is always completely charged In this case the connected loads are supplied via the line filter with offers a effective protection against mains over voltage and mains voltage peaks In the event of a mains failure PROTECT HOME supplies voltage until the battery is discharged allowing you to shut do...

Page 11: ...cted only receptacles without UPS protection Battery power supplied receptacles with UPS protection e g power failure Mains line for UPS with shockproof socket 230 Vac Input circuit breaker press button after possible execution reset RESET Overload protection for SAT TV SAT receiver F connector Overload protection telephone fax modem RJ11 connector RS232 communication interface Sub D9 USB interfac...

Page 12: ...e at 230 Vac 2 6 A UPS output Output Waveform Approximately sine wave Type Sealed maintenance free A brand Battery type amount 1221 W 1 battery back up time at nominal load half load 3 min 8 min deep discharge overload protection Yes Battery Recharge time to 90 of rated capacity 8 h Ports USB and RS232 for status and measurement levels Communication Shutdown software Compuwatch For all popular ope...

Page 13: ... Guidelines The PROTECT HOME complies with the product norm EN 50091 The CE symbol on the unit certifies the compliance to the EG guidelines for 73 23 EEC low voltage and for 89 336 EEC electromagnetic compatibility EMC when following the installation instructions in the manual For the 73 23 EEC low voltage guidelines Reference number EN 62040 1 1 2003 For 89 336 EMV guidelines Reference number EN...

Page 14: ...te airflow around the unit which is free from excessive dust corrosive fumes and conductive contaminants Do not use the UPS in environments with high temperatures or humidity 5 3 Charging The PROTECT HOME is shipped from the factory with its internal battery fully charged however some power may be lost during shipping and the battery should be recharged prior to use Plug the unit into an appropria...

Page 15: ...ceptacles and one surge protected only receptacles marked Battery Backup 5 5 Connection of peripheral devices An additional outlet marked Surge Only with protection against over load but without UPS protection allows the supply of additional peripheral devices Especially powerful loads should be connected here Keep in mind that these receptacles do not provide any power during a power failure 15 ...

Page 16: ...to the Out socket at the side panel of the UPS Incoming phone fax modem line 5 7 Satellite TV protection Connect the incoming antenna line with the F connectors optional via adapter plugs IEC in the IN socket on the rear of your PROTECT HOME Use the second antenna line and connect the Out socket with the Receiver Decoder TV etc In Out 5 8 USB and serial cable computer connection To allow for unatt...

Page 17: ... The DC Start Function enables UPS to be started up when AC utility power is not available and battery is fully charged Just simply press the power switch to turn on the UPS The DC Start Function enables UPS to be started up when AC utility power is not available and battery is fully charged Just simply press the power switch to turn on the UPS To protect yourself never switch on the main switch w...

Page 18: ...t Follow Fig 1 below to remove the screws located on the bottom of the UPS to open the battery cover Fig 1 After removing the battery cover gently extract batteries from the case Follow Fig 2 Fig 2 Disconnect the two connecting wires from the batterie and replace with the same battery type Fig 3 Fig 3 Replace the batteries following the inverse sequence Take care to connect the and poles correctly...

Page 19: ... availability of IT components and data security are guranteed The CompuWatch shutdown software supports different operating systems Windows 98SE ME Windows NT 2000 XP Linux SUSE Linux RedHat Novell NetWare IBM AIX HP UX SUN Solaris Mac OS and others Refer to the manual on the CD for details about installing the software on the various operating systems Download updates via www AEGpartnernet com P...

Page 20: ...capacity specified in the spec Software not installed well Check the setting of the software Communication lost between UPS and Computer Cable is not properly connected Check if the RS232 or USB cable is firmly connected to the COM1 COM or USB of the computer and confirm the setting Red LED is lighting alarm is heard continuously Hardware error in the UPS Contact dealer If any abnormal situations ...

Page 21: ... Serial no Date of purchase Trading stamp Signature Specifications are subject to change without notice AEG Power Solutions GmbH Emil Siepmann Straße 32 59581 Warstein Belecke Germany Operating Instructions UPS BAL 8000017714_01 EN ...

Reviews: