30
15.
BEFORE CALLING
Concern
Potential Cause
Common Solution
Automatic Ice Maker
Ice maker is not
making any ice.
•
Ice maker is turned off.
• Refrigerator is not
connected to water line
or water valve is not open.
• The water supply line
is kinked.
•
The water filter is not seated
properly.
•
The water filter may be
clogged with foreign
material.
• Turn on ice maker. For the
fresh food ice maker, press
ice maker on-off button once.
• Connect the unit to the
household water supply and
ensure the water valve is
open.
• Ensure that the supply line
does not kink when the
refrigerator is pushed into
place against the wall.
• Remove and re-install the
water filter. Be sure to seat it
fully into the locked position.
• If water dispenses slowly
or not at all, or if the filter
is six months old or older,
it should be replaced.
• Although this appliance automatically
defrosts, a layer of frost may occur
on the freezer compartment’s interior
walls if the freezer door is opened
frequently or kept open too long. If the
frost is too thick, choose a time when
the supply of food stocks are low and
proceed as follows:
1.
Remove existing food and
accessories baskets, unplug
the appliance from the mains
power and leave the doors open.
Ventilate the room thoroughly to
accelerate the thawing process.
2.
When defrosting is completed,
clean your freezer as described
above.
CAUTION!
Don’t use sharp objects to
remove frost from the freezer
compartment. Only after the
interior is completely dry should
the appliance be switched back
on and plugged back into the
mains socket.
Door seals cleaning
Take care to keep door seals clean.
Sticky food and drinks can cause seals
to stick to the cabinet and tear when you
open the door. Wash seal with a mild
detergent and warm water. Rinse and dry
it thoroughly after cleaning.
CAUTION!
Only after the door seals are
completely dry should the
appliance be powered on.
WARNING!
The LED light must not be
replaced by the user! If the LED
light is damaged, contact the
customer helpline for assistance.
Summary of Contents for RMB96719CX
Page 37: ...37 ENGLISH ...
Page 71: ...71 DANSK 18 LYDE Der kommer lyde under normal drift kompressor kølekredsløb ...
Page 72: ...72 www aeg com ...
Page 108: ...108 www aeg com ...
Page 143: ...143 NORSK 18 STØY Skapet lager lyder under normal bruk kompressor sirkulering av kjølevæske ...
Page 144: ...144 www aeg com ...
Page 180: ...180 www aeg com ...
Page 218: ...218 www aeg com ...
Page 257: ...257 FRANÇAIS ...
Page 258: ...258 www aeg com ...
Page 298: ...298 www aeg com ...
Page 334: ...334 www aeg com ...
Page 335: ......