31
ENGLISH
Concern
Potential Cause
Common Solution
Ice maker is not
making enough ice.
• Ice maker is producing less
ice than expected.
•
The water filter may be
clogged with foreign
material.
• The water supply line is
kinked.
• Water pressure is extremely
low. Cut-off and cut-on
pressures are too low
(well systems only).
• Reverse osmosis system
is in regenerative phase.
• The ice maker will produce
approximately 1 kg of ice
(fresh food ice maker)
every 24 hours depending
on usage conditions.
• If water dispenses slower
than normal, or if the filter
is six months old or older,
it should be replaced.
• Ensure that the supply line
does not kink when the
refrigerator is pushed into
place against the wall.
• Have someone turn up the
cut-off and cut-on pressure
on the water pump system
(well systems only).
• It is normal for a reverse
osmosis system to be
below 20 psi during the
regenerative phase.
Ice cubes are
freezing together.
• Ice cubes are not being
used frequently enough
or interruption of power
for prolonged time.
• Remove ice container and
discard ice. The ice maker
will produce fresh supply.
Ice should be used at least
twice weekly to keep the
cubes separated.
• Ice cubes are hollow (shells
of ice with water inside). The
hollow cubes break open in
the bin and leak their water
onto existing ice, which
causes it to freeze together.
• This generally occurs when
the ice maker does not get
enough water. This is usually
the result of a clogged water
filter or restricted water
supply. Replace the water
filter and if the condition still
occurs, check to see if the
water valve is not turned on
all the way or if there is a
kinked water supply line.
Dispenser (Ice & Water)
Dispenser will not
dispense ice.
• There is no ice in the bin
to be dispensed.
• The refrigerator doors are
not completely closed.
• Dispenser paddle has
been pressed too long and
the dispenser motor has
overheated.
• See the “Ice maker is not
making any ice” section.
• Be sure the refrigerator
doors are completely closed.
• The motor overload
protector will reset in about
three minutes and then ice
can be dispensed.
Summary of Contents for RMB96719CX
Page 37: ...37 ENGLISH ...
Page 71: ...71 DANSK 18 LYDE Der kommer lyde under normal drift kompressor kølekredsløb ...
Page 72: ...72 www aeg com ...
Page 108: ...108 www aeg com ...
Page 143: ...143 NORSK 18 STØY Skapet lager lyder under normal bruk kompressor sirkulering av kjølevæske ...
Page 144: ...144 www aeg com ...
Page 180: ...180 www aeg com ...
Page 218: ...218 www aeg com ...
Page 257: ...257 FRANÇAIS ...
Page 258: ...258 www aeg com ...
Page 298: ...298 www aeg com ...
Page 334: ...334 www aeg com ...
Page 335: ......