34
Concern
Potential Cause
Common Solution
Digital temperature
displays an error.
• Electronic control system
has detected a performance
problem.
• Contact Electrolux Customer
Care for assistance.
Water/Moisture/Frost Inside Refrigerator
Moisture collects
on inside of
refrigerator walls.
• Weather is hot and humid.
• Flipper mullion
• The rate of frost buildup and
internal sweating increases.
•
Adjust flipper mullion. (See
“To adjust the flipper mullion”
in the Installation section.)
Water collects
on bottom side
of drawer cover.
• Vegetables contain and give
off moisture.
• It is not unusual to have
moisture on the bottom side
of the cover.
• Both crispers contain
an automatic humidity
control, which should adjust
automatically to the varying
levels of moisture inside
the drawer without creating
additional condensation or
drying out the air inside the
crisper drawer, works with
various types of produce.
If excess moisture is noticed,
check to verify humidity
membrane is not damaged
and replace as necessary.
Water collects in
bottom of drawer.
• Washed vegetables and fruit
drain while in the drawer.
• Dry items before putting
them in the drawer.
Water collecting in bottom
of drawer is normal.
Water/Moisture/Frost Outside Refrigerator
Moisture collects
on outside of
refrigerator or
between doors.
• Weather is humid.
• This is normal in humid
weather. When humidity is
lower, the moisture should
disappear.
Food/Drinks in Fresh Food Compartment/Multi Switch drawer
Food is freezing.
• Temperature setting is too
low.
• Temperature sensor is
covered by food (right side
of fresh food area).
• Food is covering the air ports.
• Move the setting to a higher
degree.
•
Allow space for air flow
to the sensor.
• Allow space between the
air ports and the food.
Cold Drink Timer
Drinks are freezing.
• Temperature setting
is too low.
• Cold drink timer is set
too long.
• Move temperature setting
higher.
• Reduce time of cold drink
timer accordingly.
Summary of Contents for RMB96719CX
Page 37: ...37 ENGLISH ...
Page 71: ...71 DANSK 18 LYDE Der kommer lyde under normal drift kompressor kølekredsløb ...
Page 72: ...72 www aeg com ...
Page 108: ...108 www aeg com ...
Page 143: ...143 NORSK 18 STØY Skapet lager lyder under normal bruk kompressor sirkulering av kjølevæske ...
Page 144: ...144 www aeg com ...
Page 180: ...180 www aeg com ...
Page 218: ...218 www aeg com ...
Page 257: ...257 FRANÇAIS ...
Page 258: ...258 www aeg com ...
Page 298: ...298 www aeg com ...
Page 334: ...334 www aeg com ...
Page 335: ......