14
Heavy build up of frost, pos-
sibly also on the door seal.
Door seal is not air tight
(possibly after changing
over the hinges).
Carefully warm the leaking
sections of the door seal
with a hair dryer (not hotter
than approx. 50 ¡C). At the
same time shape the war-
med door seal by hand such
that it sits correctly.
The food is too warm.
Interior lighting does not
work.
The appliance is near a heat
source.
Temperature is not properly
adjusted.
Please look in the "Initial
Start Up" section.
Light bulb is defective.
Please look in the "Chan-
ging the Light Bulb" section.
Turn the temperature regu-
lator to a colder setting tem-
porarily.
Door was open for an exten-
ded period.
Please look in the "Installa-
tion location" section.
A large quantity of warm food
was placed in the appliance
within the last 24 hours.
Open the door only as long
as necessary.
Malfunction
Possible Cause
Remedy
Appliance does not work.
Appliance is not switched on Switch on the appliance.
Mains plug is not plugged in
or is loose.
Insert mains plug.
Fuse has blown or is defec-
tive.
Check fuse, replace if
necessary.
Socket is defective.
Mains malfunctions are to be
corrected by an electrician.
Appliance cools too much.
Temperature is set too cold. Turn the temperature regu-
lator to a warmer setting
temporarily..
Something Not Working
If the appliance is not functioning correctly, please carry out the fol-
lowing checks before contacting your local AEG Service Force Cen-
tre.
Warning!
Repairs should only be carried out by qualified service engineers.
Repairs carried out by inexperienced persons may cause injury or
serious malfunctioning.