Installation
16
Fitting the plinth
Important!
For the efficient operation of the appliance, it is important that the
original ventilation grid is used.
• For an opening height dimension
A=820 mm and a plinth height
dimension a=100 mm, the plinth may
be fitted without adjustments. The
same applies to an opening height
dimension B=870 mm and a plinth
height dimension b=150 mm.
• For plinth heights greater than
a=100 mm, b=150 mm, a cut should
be made in the plinth, 580 mm wide,
in the centre of the appliance posi-
tion, leaving a remaining height of
a=100 mm, b=150 mm.
• Attach plinth to the kitchen units.
Important!
The plinth must be positioned at a minimum distance of 25 mm from
the door.
Please check whether, after installing your appliance and especially
after reversing the door, the door seal seals right round. A badly fitting
door seal may lead to heavy frosting and result in a higher power con-
sumption (see also “What to do if ...”).
008
580
a = 100
b = 150
25 - 80
A
= 820
B = 870
25
Power supply
A correctly installed, earthed socket is required for the electrical sup-
ply. The supply must have a fuse rating of at least 1
3
Amps. If the
socket is not accessible once the appliance is built in, the electrical
installation must include suitable means of isolating the appliance
from the mains (e.g. a fused spur).
Before initial start-up, refer to the appliance rating plate to ascertain
if supply voltage and current values correspond with those of the
mains at the installation location.
e.g.: AC
220 ... 240 V 50 Hz or
220 ... 240 V ~50 Hz
(i.e. 220 to 240 volts alternating current, 50 Hertz)
The rating plate is inside the appliance on the
right.
☞