Problem
Possible cause
Solution
The appliance is noisy.
The appliance is not sup-
ported properly.
Check if the appliance stands
stable.
The lamp does not work.
The lamp is in stand-by.
Close and open the door.
The lamp is defective.
Refer to "Replacing the lamp".
The compressor operates
continually.
Temperature is set incor-
rectly.
Refer to "Operation".
Many food products were
put in at the same time.
Wait some hours and then
check the temperature again.
The room temperature is
too high.
Refer to climate class chart on
the rating plate.
Food products placed in
the appliance were too
warm.
Allow food products to cool to
room temperature before stor-
ing.
The door is not closed cor-
rectly.
Refer to "Closing the door".
There is too much frost and
ice.
The door is not closed cor-
rectly or the gasket is de-
formed/dirty.
Refer to "Closing the door".
The water drainage plug is
not correctly positioned.
Position the water drainage
plug in the correct way.
Food products are not
wrapped properly.
Wrap the food products bet-
ter.
Temperature is set incor-
rectly.
Refer to "Operation" .
Water flows on the rear
plate of the refrigerator.
During the automatic de-
frosting process, frost
melts on the rear plate.
This is correct.
Water flows inside the refrig-
erator.
The water outlet is clog-
ged.
Clean the water outlet.
Food products prevent
that water flows into the
water collector.
Make sure that food products
do not touch the rear plate.
Water flows on the floor.
The melting water outlet is
not connected to the
evaporative tray above the
compressor.
Attach the melting water out-
let to the evaporative tray.
The temperature in the ap-
pliance is too low/too high.
The temperature regulator
is not set correctly.
Set a higher/lower tempera-
ture.
www.aeg.com
26
Summary of Contents for SCB41611LS