8.
Open the door. Make sure that the lamp comes on.
Closing the door
1.
Clean the door gaskets.
2.
If necessary, adjust the door. Refer to "Installation".
3.
If necessary, replace the defective door gaskets. Contact the Service Center.
TECHNICAL DATA
Dimension
Height
815 mm
Width
596 mm
Depth
550 mm
Rising Time
13 h
Voltage
230-240 V
Frequency
50 Hz
The technical information are situated in the rating plate on the internal left side of the
appliance and in the energy label.
INSTALLATION
WARNING!
Read the "Safety Information" carefully for your safety and correct operation of the appli
-
ance before installing the appliance.
Positioning
This appliance can be installed in a dry, well ventilated indoor (garage or cellar) also, but for
optimum performance install this appliance at a location where the ambient temperature
corresponds to the climate class indicated on the rating plate of the appliance:
Climate class
Ambient temperature
SN
+10°C to + 32°C
N
+16°C to + 32°C
ST
+16°C to + 38°C
T
+16°C to + 43°C
Electrical connection
Before plugging in, ensure that the voltage and frequency shown on the rating plate corre
-
spond to your domestic power supply.