background image

5

english

conTrols

A

B

C D

F

E

a: hood Functions on/off.

When the button is touched with the hood 

turned off, all functions light up (intensity 

50%) and are enabled.

When the button is touched with the hood 

in operation, all functions are turned off and 

disabled (Motor off + lights off).

B: Manages motor speed:  

0-V1-V2-V3-V4-P.

When the area is touched, the motor starts 

at the speed required.

P = Intensive speed, timed for 5 minutes, 

after which the system returns to the 

previous speed.

When activated from Motor off it returns 

to speed V1.When the required speed is 

touched, it will become brighter (intensity 

100%) than the other functions (intensity 50%).

c: Delay function.

Touching this button activates automatic 

shutdown of the Motor, the Fans and the 

lighting with a 10 minute delay. It can only 

be activated with the motor on, running at 

any speed except Intensive, and with the 

sensor = off.

Enables / Disables the Remote Control 

Receiver.

When this button is pressed and held for 

4 seconds (Motor off + lights off, in the 

absence of other alarms, the led will light 

up for:

4 seconds to indicate that the remote 

control has been activated

2 seconds to indicate that the remote 

control has been Deactivated.

D: sensor.

In this mode the hood operates 

automatically for a maximum of 5 hours, 

after which it switches the Motor off. The 

hood modifies the speed of the motor 

according to the findings of the sensor.

Buttons B and c do not work. The function 

is disabled by pressing the Button or turning 

the hood off.

e: Manages lighting Intensity: 

0-l1-l2-l3-lMax.

When this area is touched, the lights turn on 

at the required intensity. When the lighting 

intensity is touched, it will become brighter 

(intensity 100%) than the other functions 

(intensity 50%).

F: Filter resetresets the Filter 

saturation alarm when the 

button is touched with the motor 

and lighting  turned off.

after 100 hours operation the led lights 

up continuously to indicate saturation of 

the Metal Grease Filters. after 200 hours 

operation the Led flashes to indicate 

saturation of the activated charcoal Filters.

Enables/Disables the Activated Charcoal 

Filter Alarm.

When this button is pressed and held for 

4 seconds(Motor off + lights off), in the 

absence of other alarms, the led will light 

up for:

4 seconds to indicate the activated charcoal 

Filter alarm has been activated

2 seconds to indicate the activated charcoal 

Filter alarm has been deactivated.

after connecting the hood to the mains, the 

commands are activated after 4seconds. 

When the hood is switched off, none of the 

functions is displayed, and only the normal 

lettering on the control panel is visible.

all the rest will light up (intensity 50%) when 

button a is touched. 

The controls are activated by touching the 

selected function, which will light up more 

brightly (intensity 100%) with respect to 

the other hood functions (intensity 50%). 

When no commands are given for at least 

10 seconds, only the selected functions will 

be lighted (Intensity 100%) and all the rest 

will turn off (Intensity 50%). after 7 hours in 

operation, if no further commands are given 

the hood will switch off (Motor off + lights 

off), from here you can touch for activated 

the function, and the next touch you can 

select the desired function.It is possible to 

activate one of the hood functions (speed 

and lighting) not just by touching the control 

panel, but also by placing a finger on the 

panel and sliding it towards the chosen 

Summary of Contents for X99384MD0

Page 1: ...X99384MD0 X99384MD01 EN cooker hood ...

Page 2: ...EN user manual 3 ...

Page 3: ...okware to cutlery baskets from bottle holders to delicate laundry bags Visit the webshop at www aeg com shop ENVIRONMENT CONCERNS Recycle the materials with the symbol Put the packaging in applicable containersto recycle it Help protect the environment and human health and to recycle waste of electricaland electronic appliances Do not dispose appliances marked with the symbol with the household wa...

Page 4: ...room by the cooker hood If the supply cord is damaged it must be replaced from the manufacturer or its service agent use The extractor hood has been designed ex clusively for domestic use to eliminate kitchen smells Never use the hood for purposes other than for which it has been designed Never leave high naked flames under the hood when it is in operation Adjust the flame intensity to direct it o...

Page 5: ...ed intensity When the lighting intensity is touched it will become brighter intensity 100 than the other functions intensity 50 F Filter ResetResets the Filter Saturation alarm when the button is touched with the motor and lighting turned off After 100 hours operation the Led lights up continuously to indicate saturation of the Metal Grease Filters After 200 hours operation the Led flashes to indi...

Page 6: ... out every time the type of hob is changed Calibration procedure every time the hood is turned on or the type of hob is changed the sensor calibration procedure is run During this time the hood must not be used for cooking or subjected to particularly intense smells for example solvents or detergents This process requires 13 minutes if the electric hob has been selected 1 minute if the gas hob has...

Page 7: ......

Page 8: ...436005782_02 130121 www aeg com shop ...

Reviews: