30
15
Automatic Alarm Recovery
This series of refrigerator is has an automatic alarm recovery feature.
Remote alarm terminals are installed on the
refrigerator and the alarm signal behind the
compartment is output by the terminals. The
bearing capacity of the terminals is DC 30V, 2A.
Terminal output:
Remote alarm terminals include NO, NC and COM.
The user can choose “NO” or “NC” if needed.
EL-R/G 12H/14H/16H/31H/33H
has remote alarm terminals:
When the system is in the alarm mode, you can press the “Silence” on the display panel to
cancel the alarm. (The remote alarm will not be stopped.)
If the alarm condition still exists, the buzzer will return to the alarm mode again
automatically 20 minutes later.
EL-RG-9H
/
14H
series does not have the remote alarm function.
Remote Alarm Terminals
COM
NO
NC
Pad lock
Solid door
Control panel
Light switch
USB port
Door
lock
Door ajar
alarm switch
Battery
switch
Handle
EL-R-16H
Caster
Leveling leg