Microprocessor control, digital display of temperature, temperature
display accuracy as 1
℃
and temperature range as 2
℃
~8
℃
.
Multi-fault alarm (high and low temperature alarm, power failure
alarm, sensor error alarm and door ajar alarm,low battery alarm)
Two alarm methods (audible buzzer and visual)
All independent components are safely grounded
Optimized refrigeration system, hermetically sealed refrigeration
compressor
User-friendly design, Microprocessor control, smart and carefree,
adjustment not required
High-performance thermal insulation layer, with excellent insulation
effect
Automatic condensate removal, no drain lines required
Note: Technical information might be somewhat different on your refrigerator than
published due to continuous improvement.
The product is applicable to pharmacies, pharmaceutical factories, quarantine stations, health
centers and hospitals, used to store biological products and those need to be stored at a
temperature between 2~8
℃
.
20
1
EL-R-4H
597×635×835
515×415×630
118L
3/1
R134a 85g
LED 0.3W
46kg
2
℃
~8
℃
220V-240V~/50/60Hz
165W/1.16A
EL-RG-4H
597×635×835
515×415×630
118L
3/1
Microprocessor controlled
R134a 90g
LED 0.3W
41kg
2
℃
~8
℃
220V-240V~/50/60Hz
135W/1.03A
Solid door
CFC-Free foamed-in-place urethane
High Quality Hermetically sealed compressor
Force-air cooling circulation
Glass door with electric heat
Force-air cooling circulation
Pharmaceutical Refrigerator
Exterior Dimensions
(W×D×H)
(mm)
Interior Dimensions
(W×D×H)
(mm)
Effective Volume
Door
Insulation
Compressor
Shelves/Basket
Refrigerating Method
Exterior / Interior
Condenser/Evaporimeter
Refrigerant
Lamp
Net Weight
Temperature Range
Voltage
Rated Power/Current
Alarm system
High & low temperature alarm, sensor error alarm, power failure alarm,
door ajar alarm
,
low battery alarm
Name
Model
Battery duration for alarm system
at least 8h (when the battery is fully charged)
Anti-shock Safety Classification
I
I
Temperature Control
Power connection type
Y
Y
Climate Type
4
4
Foaming Agent
CP/IP
CP/IP
Noise Level(Lp)
32dB(A)
32dB(A)
Microprocessor controlled
Max:10kg/m²
Load
Max:10kg/m²
Note: Climate Type 4 means the temperature is +30
℃
,the relative humidity is 55%.Technical information may vary from
the appliance that you have just purchased due to technical improvements.
Wire and tube / Plate type
Wire and tube / Plate type
sprayed steel plate /PS plate
sprayed steel plate /PS plate
Automatic defrost maintains optimum cooling capacity