14
Product Installation
Normal operation will be impossible for refrigerator if it is installed in
environments other than those described above as it is sensitive to ambient
temperature. Start operation after the environment is improved.
It is prohibited to install the refrigerator outdoor. Electric leakage or shock may
be caused if the refrigerator gets wet by rainwater.
The installation site shall meet following requirements for normal operation and best performance of
refrigerator:
Do not install the refrigerator in a narrow and confined space and the door of the installation space
may not be smaller or lower than the refrigerator, to ensure smooth entry and exit of the refrigerator
as well as to prevent damage to the stored articles due to not timely repair of refrigerator as the
installation site is not easy to be accessed.
The ground at the installation site shall be solid and flat.
It is well ventilated and free from direct sunshine.
Do not share the same power outlet with other equipment. The power plug must be plugged into
the outlet securely.
Do not twist or compress the power line.
If the power line needs to be extended, the extended line shall be no smaller than 3mm² in
sectional area and no longer than 3m.
Check the operating voltage before operation and voltage regulator appropriate for motor load may
be applied in regions with unstable voltage.Ensure the normal input voltage stands at rated
voltage ± 10% and the power of voltage regulator is greater than 400W.
The refrigerator shall be grounded in a reliable manner.
If the socket is provided with grounding wire, check if it is well grounded before operation.
If the socket is not provided with grounding wire, a new one shall be installed by professional
engineers.
Installation environment
Ambient temperature: 16
℃
to 32
℃
, 18
℃
to 25
℃
are optimal and air conditioning system is
required as necessary.
Ambient humidity:
EL-R-2.4H
: below 70%Rh;
EL-RG-2.4H
:below 75%Rh;
EL-RG-4H
/
EL-R-4H
below 85%Rh.
Avoid excessive dust.
Avoid mechanical swing or vibration.
The refrigerator shall operate at an altitude lower than 2000m.
Input voltage: no greater than ±10% of rated voltage.
Installation site
Do not ground the refrigerator through gas pipes, water supply pipes, telephone
lines or lightning conductors as electric shock may be caused.
The power plug should be accessed after installation to ensure the power line
can be pulled immediately in case of an emergency. The air vents should be
free from any obstruction.
7
Display
6.Check recent highest and lowest cabinet temperature: See fig #1
Press both “Set” and “+” buttons to check the most recent cabinet temperature. Release the
buttons to return to the cabinet temperature display.
Press both “Set” and “-“ buttons to check the most recent cabinet temperature. Release the
buttons to return to the cabinet temperature display.
7.Adjust alarm temperature range: See fig #1
The method sets high temperature alarm “HA” and low temperature alarm “LA”.
Press “Alarm” button for 10 seconds. LED display code “HA” , press “Set” button again (quickly),
code ”HA” flash, adjust the set-temperature by both pressing “+” and “-” buttons and increment 1
℃
,
adjustment range should’t be 6
℃
higher than pre-set cabinet temperature, press “Alarm”button to
return the former menu(each press of “Alarm” button will return one step back to former menu until
display cabinet temperature) and LED display “HA” . Press both “+” and “-” to choose another
parameter “LA” , “LA” setting method like “HA”, and its adjustment range shouldn’t be 6
℃
lower
than pre-set cabinet temperature.
8.Defects display
The control panel only can display one sensor error, when the sensor error happens . LED display
“EE”, and alarm at the same time. The refrigerator will keep working according to the defect safety
model , and you should put the stored goods to other refrigerator as soon as possible, and contact
the after-sales department quikly.
9.Inner light
In order to see the stored goods clearly, a LED light has been installed in the cabinet. You can
control light “on” or “off” by “light” button to save energe, please turn off the light after observing the
stored goods in the refrigerator.
The light is on when the door is open; The light is off when the door is closed.
10.Power failure alarm function
5.Check alarm temperature: See Fig #1
Press both “Set” and “+” buttons to check the most recent cabinet temperature. Release the buttons
to return to the cabinet temperature display.
Press both “Set” and “-“ buttons to check the most recent cabinet temperature. Release the buttons
to return to the cabinet temperature display.
When the power is down, power-off alarm function is activated, buzzer with 1 Hz frequency
continuously beeps,at the same time alarm indicator light of the board flashes, if alarm equipment
is connected to the remote alarm port, it will alarm synchronously and last at least 8 hours. Press
the "Alarm" button to cancel the power off alarm, while the remote alarm function is cancelled.