  DOOR FORCED OPEN WARNING & TIMING                                             (Location 80)

(1) LOCATION 

Key in Location

(2) FUNCTION MODES FOR DOOR FORCED OPEN WARNING

The Door Forced Open Warning function works with a Door Position Sensing switch equipped on the 
door (usually a magnetic contact). Once a Timing Figure is put into the Function Mode box, the 
warning mode is enabled.

 --- 

Door Forced Open Warning OFF – (Default)

 - 

 --- 

Door Forced Open Warning & Alarm Enabled & Timing

The Timing Figure for the Warning can be 1-999 seconds. The keypad generates the door forced 
open warning beeps and activates the alarm output (Terminal 12) instantly if the door is forced to 
open without a valid User Code/Card or pressing of Egress Button. The beeps and alarm will last as 
long as the time set on the timer and it can be stopped at anytime with an User Code/Card in Group 
1 before the end of the time.

The Manner of The Door Forced Open Warning:

a) The door is forced to open (without using Code/Card or Egress Button) – 

Warning & Alarm

b) The door is opened with Code/Card – 

No Warning or Alarm

c) The door is opened with Egress Button – 

No Warning or Alarm

(3) VALIDATION

Press 

 key once. Two-beep confirms the entry

  DOOR PROPPED-UP WARNING & THE DELAY TIME                               (Location 81)

(1) LOCATION 

Key in Location

(2) FUNCTION MODES FOR DOOR PROPPED-UP WARNING

If somebody opened the door and left it open longer than the allowable delay time, the keypad will 
generate door propped-up warning 

until the door is re-closed

. There is warning beeps from the 

keypad only but it does not activate the alarm output. This function works with a door position 
sensing switch equipped on the door.

 --- 

Door Propped-up Warning OFF – (Default)

 - 

 ---

 Door Propped-up Warning ON & The Delay Time

The Delay Time can be 1 to 999 seconds. It is the allowed time for door open without starting  
warning.

(3) VALIDATION

Press      key once. Two-beep confirms the entry

FUNCTION MODES

VALIDATION

LOCATION

 or 

 - 

(2)

(3)

(1)

FUNCTION MODES

VALIDATION

LOCATION

 or 

 - 

(2)

(3)

(1)

Summary of Contents for DK-2822

Page 1: ...DK 2822 User Manual MK II FOR ELECTRIC LOCK INTER LOCK AND SECURITY SYSTEM RFID ACCESS CONTROL KEYPAD DK 2822 ...

Page 2: ...ser Code Common User Codes for Output 1 2 User Codes Card For Output 1 2 Examples Programming And Operation Visitor Codes For Output 1 Only Duress Codes For Outputs 1 2 Operation And Function of The Duress Code Output Modes Timing for Output 1 and 2 System Real Time Clock Start Stop Times For Daily Inhibition of Output 1 Personal Safety And System Lock Out User Code Entry Mode Auto or Manual Pacif...

Page 3: ... APPLICATION EXAMPLES A Stand Alone Door Lock An Inter Lock System Using Two Keypads APPLICATION EXPANSIONS The Axiliary Readers Keypad The Split decoders 1 Dual station Access Control Door Lock 2 Multi station Access Control Door Lock 3 Split decoded Access Control Door Lock 4 Split decoded Multi station Access Control Door Lock APPLICATION HINTS FOR THE AUXILIARY TERMINALS AUXILIARY INFORMATION ...

Page 4: ...ith the optional decoder and multi station operation for user convenience with the auxiliary keypad readers The keypad is ideal for access control and alarm system arm disarm control It is also a programmable industrial timer from 1 second to over 24 hours for automatic operator system A member of the Tri Tech series keypads compatible with the optional controllers reader keypads for system expans...

Page 5: ...tact your local agent for the optional devices OPTIONAL DEVICES FOR SYSTEM EXPANSION The Optional Decoders Available for Split decoded Operation DA 2800 Full Feature Decoder with RF Remote Control DA 2801 Full Feature Decoder The Auxiliary Reader Keypad Available for Multi station Operation AR 2802S or A EM Card Reader AR 2806S or A EM Card Reader with Digital Keypad AR 2807S or A EM Card Reader w...

Page 6: ... 99 999 Seconds Over 24 Hours possible Independent Programmable Timers for O P 1 2 Egress Button Programmable for Instant Delay with Warning and or Alarm Momentary or Holding Contact for the Exit Delay Input Sensing Terminals a Door position b Egress c O P 1 inhibit Output Control Terminals Transistor Open Collector 24VDC 100mA sink Max for the following outputs a Duress b Alarm c Key Active d Out...

Page 7: ...ly all the wirings are correct before applying power to the system for testing 1 Prevent Interference The EM Card reader is working at the frequency of 125Khz Installation precautions are necessary 2 Prevent Accidental Short Circuit In the previous experience most of the damages caused in the installation are accidental touching of the components on circuit board with the wires carrying power Plea...

Page 8: ...ic door lock strike it switches to in operation It is selectable for operating Fail safe or Fail secure electric lock via jumper setting Connect the negative side of the electric lock to this terminal and the positive side to terminal 5 The operating time of the contact is programmable See Location 51 Important Set Output Mode for Door Lock Two types of electric locks are available on the market I...

Page 9: ... C terminal 11 is Normally Open N O and terminal 10 is the common point of the two contacts It is programmable for Start Stop toggle mode or Momentary with timing See programming Location 52 for the details 9 OUTPUT 2 Open Collector Output An NPN transistor open collector output is for the version B keypad which is controlled by the Group 2 User Codes Cards It has the maximum power rating of 24VDC...

Page 10: ...r to Ground if not used a Door Auto Re lock b Door Forced Open Warning c Door Propped up Warning The system immediately re locks the door after it is re closed before the end of the programmed time for output 1 It prevents unwanted tailgate entry The keypad generates door forced open warning and alarm instantly once the door is forced to open without a valid user Code Card or egress button The war...

Page 11: ...ing Use this output point to make cross wire connection with the partner keypad s O P 1 Inhibit point in an Inter lock system to prevent both doors can be opened at the same time An Inter lock System An inter lock system is a two door system that always allows only one of the doors to open during the operation While one of the doors is opened the other door keeps close until the open door is re cl...

Page 12: ...amming option at Location 72 The Standby flashing can be ON or OFF through the programming option at Location 73 The keypad gives dim backlit in standby It turns to full backlit when a key button is pressed then back to dim backlit 10 seconds after the last key button is pressed The backlit is OFF in standby It turns to full backlit when a key button is pressed then back to OFF 10 seconds after th...

Page 13: ... owner s selection of security level See programming Location 10 20 1 EM Card Only Operation Media 1 A general way for access control just simply read a card to open the door Security level is moderate but it is user convenient 2 User Code Only Operation Media 2 A general way for access control just simply enter a code to open the door Security level is moderate but it is user convenient 3 EM Card...

Page 14: ...program the user codes and cards smoothly and to trace them afterwards in the future Here is a suggested format of the list List of Users See page 22 25 for reference 5 EM Card Proprietary Secondary User Code Operation Media 3 The keypad accepts programming with each card having its own proprietary user code to work It prevents any other people can use the lost card to open the door Card with prop...

Page 15: ... The Mains LED amber is ON after the keypad confirms it in programming mode with 2 beeps d DO NOT turn off power while the keypad is in programming mode Otherwise it may cause error to the data in memory PROGRAMMING OPERATION POWER UP THE KEYPAD The keypad gives power up delay of 1 minute after power has been applied It is the time frame designed for setting the keypad to programming mode with DAP...

Page 16: ...g Re program of the desired values are necessary DIRECT ACCESS TO PROGRAMMING MODE WITH DAP CODE 2 8 2 8 In case the Master Code is forgotten apply the following procedures precisely to set keypad into programming mode with DAP code 1 2 3 4 Switch OFF all the power for 1 minute to ensure that the keypad is fully discharged Switch ON power again The keypad is in Power up Mode for 1 minute The buzze...

Page 17: ... User Program Required 9 3 Wiegand Output Format Code 1 26 Bit 9 4 Operation Modes Code 0 Keypad Mode 6 0 Personal Safety Lock out Code 1 10 False Code Card Lock out 60 Sec 7 0 User Code Entry Mode Code 2 Manual Entry Mode 7 1 7 2 O P Operation Announcer 7 3 Status LED Standby Flashing ON OFF Code 1 Flashing Enabled 8 0 Door Forced Open Warning Timing Code 0 Warning Disabled 8 1 Door Propped up Wa...

Page 18: ...ATION Key in Location 2 MASTER CODE 3 VALIDATION Master Code is the authorization code for setting the system to programming mode It is NOT an User Code operating the output relays The Master Code can be 4 to 8 digits When a new master code is keyed in and confirmed the old master code is replaced The master code is also the Link up Code between the keypad and the optional decoder in Split decoded...

Page 19: ...ride The Door Lock Controlled by Output 1 Keep Door Un locked The Output 1 is usually for door lock control In some situations the door may require un locked for a period of time to allow door opening without User Code or EM Card for entry exit convenience This function Starts Stops in toggle with the following code entry The Door is Un locked Start Stop in Toggle NOTE SUPER USER CODE SUPER USER C...

Page 20: ...nside Once the Output 1 for door lock control is inhibited all the User Codes Cards for it become invalid and those people holding the User Code or Card are refused This function Starts Stops in toggle with the following code entry Door Lock Operation Inhibited Start Stop in Toggle NOTE The door is locked during Output 1 inhibited and the INHIBIT LED Red is ON Inhibition applies to all User Codes ...

Page 21: ...tion NOTE Common User Code alone can NOT operate the Outputs directly LOCATIONS COMMON USER CODE VALIDATION 1 LOCATIONS Location Stores The Common User Code for Output 1 Location Stores The Common User Code for Output 2 2 COMMON USER CODES The Common User Code can be 4 to 8 digits When a new Common User Code is keyed in and confirmed the old one is replaced 3 VALIDATION Pressing key to confirm cod...

Page 22: ...ards in User Group 2 Output 2 4 CARD USER CODE Read EM Card or key in User Code into each assigned User ID 5 VALIDATION Press the key once Two beep confirms the entry NOTE a The Secondary User Code is a user code putting after a card in programming It can be a proprietary user code for each user card or a code repeatedly used for a group of user cards as group user code e g for a group of staff wo...

Page 23: ...a Read the EM card Two beep confirms the card is read and Output 1 activates 2 Example 2 Private User Code Only i Programming a b c d e a The Private User Code is programmed for operating Output 2 b The operation medium is Private User Code only c Take ID number 001 in Group 2 to store the Private User Code which is one of the IDs in 001 100 d Put Private User Code 1 2 3 4 into the storage locatio...

Page 24: ...th the key Output 1 activates Read Card Read Card 4 Example 4 EM Card Common User Code i Programming a b c d e a The card is programmed for operating Output 1 b The operation medium is EM Card Common User Code c Take ID number 003 in Group 1 to store the card which is one of the IDs in 000 999 d e Press to store the Card Two beep confirms a valid entry ii Operation while the system is back to oper...

Page 25: ...te An User Code or EM Card for O P 1 or 2 i Delete An User Code or A Lost EM Card a b c d a Key in the User Group that the User ID belongs to 10 for Group 1 and 20 for Group 2 b Key in 5 that is the Command Code for making a deletion c Key in the User ID that stored the User Code the lost EM card or the EM Card User Code d Press the key Two beep confirms a valid entry and the Code and or Card in t...

Page 26: ...er use Time Limit in Hour s The Visitor Code can be set with the valid time limit of 1 Hour to 99 Hours with a two digit number of 01 to 99 The visitor code is cleared by the system when the time limit reaches 4 8 DIGITS or VISITOR CODE VALIDATION LOCATION VISITOR ID VALID PERIOD 5 4 3 2 1 Clear all the Visitor Codes in Location 40 Please see the Programming example below for the details 4 VISITOR...

Page 27: ...is valid for three hours a b c d e a Visitor Code Programming b The Visitor ID c Valid for 3 Hours d The Visitor Code e Example 3 Delete a Visitor Code from Vistor ID 02 in the memory a b c a Visitor Code Programming b The Visitor ID c Delete Confirmation Example 4 Clear all Visitor Codes in Location 40 a b c a Visitor Code Location b The Deletion Command Code c Confirmation all Visitor Codes are ...

Page 28: ...tion group Please see the programming example below for the details 3 THE DURESS CODES 50 and 10 Duress Codes can be programmed for Output 1 and 2 respectively They are stored in their two digit Code ID box When a new Code is put into the same Code ID box the old code is replaced 4 VALIDATION Press key once Two beep confirms the entry The Duress Codes are 4 8 digits for Manual Mode code entry The ...

Page 29: ...ke a normal User Code The Duress Code always activates the Relay Output in its group but does not de activate stop the Duress Output ONLY a normal User Code or Card in anyone of the user groups or a Super User Code can reset de activate the Duress Output For Example Key in The Duress Code 3 3 6 9 of the Group 1 for Output 1 To Command The Duress Function Duress Output activates switches to ground ...

Page 30: ...sts Operation Taking Duress Code 3 3 6 9 in Group 1 for Output 1 As Example a b c a Read the EM card Two beep confirms the reading and 30 seconds waiting time is given for the entry of Duress Code the Amber LED keeps flashing b Key in the Duress Codes 3 3 6 9 for operating Output 1 c Confirm it with the key Output 1 activates in a normal way and the Duress Output also activates to report Duress Ev...

Page 31: ...n an User Code and or Card is entered read the output Stops when an User Code and or Card is entered read again Seconds Momentary Default Momentary 5 Seconds The output can be set in Momentary Mode with the time of 1 second to 99 999 seconds The output will reset automatically when the time expires 3 VALIDATION Press key once Two beep confirms the entry RESET OUTPUT TIMER WITH SUPER USER CODE The ...

Page 32: ...e setting and the clock starts to count in 24 hour basis from the programmed current time Programming Examples a Set the current time of 10 30 AM to the keypad b Set the current time of 6 45 PM to the keypad IMPORTANT NOTE 1 The real time clock stops after power failure which makes the real time inhibition loses its time base It is necessary to re program the system s real time clock unless the ke...

Page 33: ...2 START TIME Set the real time inhibition starting time in Hour and Minute The allowed time figure is 00 00 23 59 The starting time is based on 24 hours daily with the first two digits for hours and the last two digits for minutes The time in second always starts at 0 0 3 STOP TIME Set the real time inhibition stopping time in Hour and Minute The allowed time figure is 00 00 23 59 The stopping tim...

Page 34: ...ser Code Programming and Operation Examples i Set the starting and stopping time for the real time inhibition period a Set Inhibition Period from 12 30 PM today 1 30 PM same day for lunch time b Set Inhibition Period from 6 30 PM today 8 15 AM next day for office close NOTE 1 The start and stop time figures are 24 hours basis They are 4 digit figures from the smallest 00 00 to the largest 23 59 2 ...

Page 35: ...utput to switch to Selection of after 5 to 10 successive Card User Code trials the keypad locks during Example Release the lock up Disappearance of all the above lock up securities 3 VALIDATION Press key once Two beep confirms the entry SUPER USER CODE 1 to 2 Digits LOCK UP OPTIONS VALIDATION LOCATION 3 2 1 Default ground The Duress Output can be released with any user Code or Card in the User Gro...

Page 36: ...ATION Key in Location 2 FUNCTION MODES FOR PACIFIER TONES Pacifier Tone is the Beep Tones from the keypad which include the tones of Successful Key entry 1 beep and the Unsuccessful User Code Card entry 5 beeps NOTE The beeps for the Warning and the Power up Delay do not belong to pacifier tones and can not be OFF Pacifier Tone ON Default Pacifier Tone OFF 3 VALIDATION Press key once Two beep conf...

Page 37: ...ind the flashing light of the status LED the amber LED is annoying during standby especially at the night time The standby flashing can be ON OFF with the setting here Standby Flashing ON Default The Status LED gives Standby Flashing all the time It also gives the light indications showing the operation status of the system Standby Flashing OFF The Standby Flashing is OFF but it does not affect th...

Page 38: ...Door Forced Open Warning a The door is forced to open without using Code Card or Egress Button Warning Alarm b The door is opened with Code Card No Warning or Alarm c The door is opened with Egress Button No Warning or Alarm 3 VALIDATION Press key once Two beep confirms the entry DOOR PROPPED UP WARNING THE DELAY TIME Location 81 1 LOCATION Key in Location 2 FUNCTION MODES FOR DOOR PROPPED UP WARN...

Page 39: ...t leave it on its default values WHERE AND WHY GOING OUT NEEDS ATTENTION Examples for some areas may need an Intelligent Egress Button Hospital Some of the patients are not allowed to leave the ward without doctor s permission An egress button with exit delay and warning beeps will help the nurse or warden to get attention to the door when the egress button is pressed Further setting of the egress...

Page 40: ...emergency case only It is usually closed and watched by guards The egress button of this keypad can be programmed to offer exit delay with warning beeps and even gives alarm output to trigger an alarm system when the door is forced to open or the door is open after the exit delay expired It is an useful tool to get attention of the person on duty WARNING Do not enable Egress Delay if instant door ...

Page 41: ...n is kept pressed during the people are waiting for the door open 2 4 3 1 Press and hold the Button No warning or alarm is given during the Egress Delay Good for the silent area The people require to press hold the button until the delay time reaches for the door open Press the Button once The system gives Warning Beeps and also activates its Alarm O P during the Egress Delay Good for door for the...

Page 42: ...d Entry confirmation Example 3 Set Egress Button in Momentary contact without delay This is the default setting a b c d a Egress function programming b Momentary contact without delay c Release door instantly d Entry confirmation pressed Output 1 activates automatically door is released when the delay time reaches Codes Cards always give INSTANT action Holding Contact The user MUST hold the egress...

Page 43: ... door is forced to open without using Code Card Alarm b The door is opened with Egress Button Alarm c The door is opened with Code Card No Alarm To prevent confusion of the alarm outputs It is suggested to disable the Door Forced Open Warning at Location 80 while Door Opening Alarm function is enabled If both functions at Location 80 and Location 91 are enabled and are set with different timings t...

Page 44: ...rds and codes and five beeps for the non registers The keypad follows the lock up setting at Location 60 Wiegand Data Output Enabled Mode C This is the Reader Mode of the keypad It gives Wiegand data output for ALL the cards and codes that are read no matter they are registered or not registered in memory This mode makes the keypad to work as an independent keypad or as a server of a split decoded...

Page 45: ...Bit bit 19 bit 36 3 VALIDATION Press key once Two beep confirms the entry 1 LOCATION Key in Location 2 WIEGAND FORMAT FOR EM CARD USER CODE The Wiegand data output is programmable for 26 bit 34 bit or 37 bit standard format 26 Bit Wiegand Data Output Default Bit 1 Even Parity Bit bit 2 bit 13 Bit 2 Bit 25 24 Bit ID Number Bit 26 Odd Parity Bit bit 14 bit 25 WIEGAND FORMAT VALIDATION LOCATION or 2 ...

Page 46: ...ads for multi station expansion Server Mode Server Mode sets the keypad to compatible with both the decoder for split decoded operation and the auxiliary readers keypads for multi station expansion A split decoded keypad system uses the keypad s for human interface outside and the internal decoder for door lock control to prevent sabotage 3 VALIDATION Press key once Two beep confirms the entry or ...

Page 47: ...amming Mode Note If the Master Code is forgotten use the DAP Code to set the system into programming mode See DAP CODE 2828 in page 15 for the details 2 Change The Factory Set Master Code to Owner s Private Master Code for Security Reason 3 Record an EM Card to Operate The Output 1 for Door Open a b c d e a 10 Programming Location for Output 1 b 1 Programming option for EM Card only c 001 One of t...

Page 48: ...first Common code can be used for all the EM Cards in this operation mode REMARK If more User Codes and Cards are required for Output 1 repeat the procedures 3 4 5 or 6 above with other User IDs such as 005 006 007 999 etc Total 1 000 users are allowed See Programming Location 10 for the details 7 Close The Programming Mode 2 beeps The programming mode is closed The keypad is back to normal operat...

Page 49: ...Wiegand Data Output Port This output port provides the D0 Wiegand data from reading a card or user code Connect it to the D0 input port of the controller 3 BUZ Brown Buzzer Control Input The internal buzzer of the keypad is 0V activation It provides the audible feedback indication from the controller Connect it with the buzzer output port of the controller 4 LED Yellow LED Lamp Control Input The i...

Page 50: ... 0 stays at the high voltage The high voltage level in the keypad unit is 5VDC to accommodate for long cable runs approximate 500 feet from it to the associated controller typically located in a secure closet 50 uS pulse Data 0 Line 2 mS pulse interval Data 1 Line 0 1 0 1 5V 0V 5V 0V Wiegand Data 26 Bit 34 Bit or 37 Bit Selection The Wiegand data output is programmable to 26 bit 34 bit or 37 bit s...

Page 51: ... also marked with a 3 digit 5 digit code that are the site code and ID number arrangement of the Wiegand data EXAMPLE a The Code Marked on One of The EM Cards b Each Hex Number Consists of 4 Bits Total 26 Bits of Wiegand Data Output from Card Reading E 6 4 E B 1 3 O An Even Parity Bit of 6 4 E 0 An Odd Parity Bit of B 1 3 1 c The 26 bits Wiegand Data Sending Out in Hex Binary from Reading The Card...

Page 52: ...w for the explanations This precaution applies to 26 bit 34 bit and 37 bit Wiegand data Example A shows a 34 bit Wiegand data derived from an 8 digit User Code 12345678 Example B and C show the Wiegand outputs derived from User Codes 1234 and 00001234 Their Hex binary codes derive from the two User Codes in Wiegand format are identical and can not be discriminated from each other EXAMPLE 0 1 0 0 1...

Page 53: ...0 1 1 0 1 0 0 1 0 0 The 34 bits Wiegand data sending out in Binary from entry of the Code 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 E 0 0 0 0 0 4 D 2 O E 0 0 0 0 0 4 D 2 O 1 1 0 1 0 0 1 0 0 B The keyed in Code is 1 2 3 4 The Code in Decimal Number 1 2 3 4 The Code 1 2 3 4 Equivalent to Hex Number 4 D 2 C The keyed in Code is 0 0 0 0 1 2 3 4 The Code in Decimal Number 0 0 0 0 1 2 3 4 The Co...

Page 54: ...1 50 CODE 2 VALID PERIOD 00 One Time 01 99 Hours CODE 3 VISITOR CODE 4 8 Digits CODE1 CODE2 CODE3 NIL 4 1 Duress Code for O P 1 CODE ID O P 1 01 50 CODE ID O P 2 01 10 DURESS CODE 4 8 Digits CODE ID DURESS CODE CODE ID NIL 4 2 Duress Code for O P 2 NIL 5 1 O P Mode for O P 1 OUTPUT MODE TIME 0 Start Stop 1 99999 Seconds START TIME 00 00 23 59 STOP TIME 00 00 23 59 5 6 Start Stop Times for Inhibiti...

Page 55: ...g 2 Momentary with warning 3 Momentary with warning Alarm 4 Hold Contact No warning 5 Hold Contact with warning 6 Hold Contact with warning Alarm CODE 2 DELAY TIME 0 No Delay 1 99 Seconds CODE 1 CODE 2 Mode 1 Momentary No warning TIME 0 No Delay 9 1 Door Opening Alarm TIMER ALARM TIME 0 No Alarm 1 999 Seconds ALARM TIME Time 0 No Alarm 1 2 3 4 9 4 Operation Mode FUNCTION MODE MODE Mode 0 Keypad Mo...

Page 56: ... default values All programmed data are cleared and back to the default values except the Master Code 2 8 2 8 DAP CODE Direct access to programming mode Valid only in the power up delay period System in Programming Mode 0 9 9 9 USER Codes Cards whole group clearing Code for the selected Location LOCATIONS 10 User Group 1 20 User Group 2 40 Vistor Group 41 Duress Group 1 42 Duress Group 2 LOCATION ...

Page 57: ...ng the keypad To avoid Electro Static Discharge from interfering with the operation of the keypad always ground the terminal of the keypad to earth Always connect DOOR SENSOR terminal to ground if not used DK 2822 TAMPER N C DOOR LOCK DATA I O N O EGRESS BUTTON INSIDE HOUSE 5 6 7 8 1 2 3 4 ELECTRIC LOCK CATHODE IN4004 See Door Lock Selection Jumper 1 SAFE For Fail Safe Electric Lock 2 SECURE For F...

Page 58: ... outside Press egress button to open the door from inside Connect the door magnetic sensors on the doors to monitor their positions While door 1 is open then door 2 is forced to keep close or vice versa Use N O Relay output for fail secure lock and N C output for fail safe lock Please also see the NOTE stated in the Application Example 1 DATA I O DATA I O EGRESS BUTTON OPEN DOOR 1 FROM INSIDE TAMP...

Page 59: ...otage at the external keypad s A Split decoded system is also compatible with the auxiliary keypads for multi station operation It is a perfect system for overall higher security and user convenience The application examples here show the connections of the auxiliary keypads and the decoder to the server keypad Please contact your local agent for these optional devices if increasing security and u...

Page 60: ...COLLECTOR OUTPUT OPEN COLLECTOR OUTPUT 1A RELAY DRY CONTACTS FOR AUXILIARY CONTROL 1A RELAY DRY CONTACTS FOR AUXILIARY CONTROL 5A RELAY DRY CONTACTS FOR DOOR STRIKE OPEN COLLECTOR OUTPUT OPEN COLLECTOR OUTPUT INPUT OUTPUT FOR SPLIT DECODED SIGNALS POWER OUTPUT FOR KEYPADS COMMON GROUND POWER INPUT FOR SYSTEM N C SW COMMON GROUND N C SW N O SW N O SW N O SW OUTPUT 1 OUTPUT 2 OUTPUT 3 Standard Decod...

Page 61: ...master keypad If it is an auxiliary reader keypad it accepts cards and user codes like the master keypad Note Keep Operation Mode setting of the keypad in Keypad Mode default with Location COMMON GND POWER SUPPLY DATA I O BUS DK 2822 MASTER KEYPAD AR 2802 S or A AUXILIARY READER ELECTRIC LOCK Wiring Diagram System Connection Dual Station Access Control Door Lock 94 0 in this application 6 5 4 3 2 ...

Page 62: ...e Keep Operation Mode setting of the keypad in Keypad Mode default with Location COMMON GND POWER SUPPLY DATA I O BUS DK 2822 MASTER KEYPAD AR 2802S OR AR 2802A AR 2802S OR AR 2802A AUXILIARY READER ELECTRIC LOCK COMMON GND POWER SUPPLY DATA I O BUS MASTER KEYPAD 6 5 4 3 2 1 LED DATA I O TAMPER N C 12 24V DC 6 5 4 3 2 1 LED DATA I O TAMPER N C 12 24V DC Wiring Diagram System Connection AR 2806 OR ...

Page 63: ...OM N C TAMPER GND DOOR SENS O P 1 INHIB INT LOCK DU OUT DOOR BELL IN EG IN DATA I O KEYPAD PWR GND 12 24V DC N O ELECTRIC LOCK 1N4004 CATHODE OUTPUT RELAY 1 N O Output for Fail secure Lock N C Output for Fail safe Lock N C OUTPUT 1 OUTPUT 2 OUTPUT 3 DIGITAL KEYPAD EGRESS BUTTON MORE EGRESS BUTTON CAN BE CONNECTED IN PARALLEL DOOR BELL BUTTON N O N O N O AD 1312 OR AP 960 COMMON GND POWER SUPPLY DA...

Page 64: ...ting of the keypad in Server Mode with Location 94 1 in Wiring Diagram System Connection 6 5 4 3 2 1 LED DATA I O TAMPER N C 12 24V DC AR 2802 06 07 09 AUXILIARY READER OR KEYPAD READER DK 2822 SERVER ALARM O P KEY ACT O P N O COM N C N O COM N C N O COM N C TAMPER GND DOOR SENS O P 1 INHIB INT LOCK DU OUT DOOR BELL IN EG IN DATA I O KEYPAD PWR GND 12 24V DC N O ELECTRIC LOCK 1N4004 CATHODE OUTPUT...

Page 65: ...a small buzzer to notify a guard or connect it to a 24 hour Normally Open protection zone of an alarm system See Location 80 and Location 91 for more information about these functions Door Auto Relock The system will immediately relock the door after a valid access has been gained to prevent tailgate entries Door Forced open Alarm The keypad will generate alarm instantly if the door is forced to o...

Page 66: ...nd low voltage to prevent damage of the keypad Only one connection option is recommended Make sure the sink current does not exceed the maximum rating of 100mA External power supply and isolation relay are strictly necessary in driving high power device such as lights The Duress Output switches to ground when duress code is entered You may use it to turn ON an LED lamp and or a small buzzer to not...

Page 67: ... or N C output contact to make arm disarm control of an alarm system Consult your alarm control panel manual for the appropriate output contact for arm disarm control Usually set output 2 to Momentary mode Programming Option 521 Location 52 Output Mode 1 for multi station systems and Start Stop mode Programming Option 520 Location 52 Output Mode 0 for single station systems ii Alarm System Arm Dis...

Page 68: ... It is open circuit when active N O Normally Open the contact is open circuit at normal status It is closed circuit when active TRANSISTOR OPEN COLLECTOR OUTPUT An open collector output is equivalent to a Normally Open N O contact referring to ground similar to a relay contact referring to ground The transistor is normally OFF and its output switches to ground when active The open collector can on...

Page 69: ...cy energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to c...

Page 70: ...AEI PROTECT ON SYSTEMS LIMITED www apo hk com Ver 202002_V2 ...

Reviews: