SPECIFICATIONS
6
Operating Voltage:
12V DC Nominal; 11-15V DC
Operating Current:
60mA (quiescent) to 95mA
Operation Temperature:
-20 C to +70 C
Environmental Humidity:
5-95% relative humidity non-condensing
Working Environment:
Indoor use only
Number of Users:
Output 1 – 1,000 (PINs and/or Cards) + 50 Duress Codes
Output 2 – 100 (PINs and/or Cards) + 10 Duress Codes
Proximity Card:
Standard EM Card or Keyfob, 125Khz
Number of Visitor Codes:
50, programmable for one time or with the time limit
Timings for Code Entry and Card Reading:
10 seconds waiting for next digit entry
30 seconds waiting for code entry after card reading
The Timers:
Three 1-99,999 Seconds (Over 24 Hours possible) Independent Programmable Timers for O/P
1 & 2
Egress Button:
Programmable for Instant, Delay with Warning and/or Alarm
Momentary or Holding Contact for the Exit Delay
Input Sensing Terminals:
a) Door position, b) Egress, c) O/P 1 inhibit
Output Control Terminals:
Transistor Open Collector 24VDC/100mA sink Max for the following outputs
a) Duress, b) Alarm, c) Key Active, d) Output 2 (Door Bell version only), e) Inter-lock
Output Contact Ratings:
Output Relay 1 – Solid State Relay, Fail-safe or Fail-secure selectable, 3A/16VDC Max
Output Relay 2 – N.C. & N.O. dry contacts, 1A/24VDC Max. (N.O. contact only for Door Bell
version)
Tamper Switch – N.C. dry contact, 50mA/24VDC Max.
Dimensions:
117(H) X 74(W) X 48(D)mm
Weight:
200g net
Housing:
ABS Plastic Box
Specifications are subject to change for modification without notice