LOCATION
PARAMETERS
DEFAULT FUNCTIONS & VALUES
0 1
Master Code
0 0 0 0 Factory Set, Not a default value *
0 2
Super User Codes
Nil ----- User Program Required
0 3
Common User Code 1
Nil ----- User Program Required
0 4
Common User Code 2
Nil ----- User Program Required
1 0
User Codes & Cards for O/P 1
Nil ----- User Program Required
2 0
User Codes & Cards for O/P 2
Nil ----- User Program Required
4 0
Visitor Codes
Nil ----- User Program Required
5 1
O/P Mode of The O/P 1
Time = 5 Sec, Momentary
5 2
O/P Mode of The O/P 2
Time = 5 Sec, Momentary
5 6
Start & Stop Time
Nil ----- User Program Required
5 5
System Real-Time-Clock
Nil ----- User Program Required
9 4
Operation Modes
Code = 0,Keypad Mode
6 0
Personal Safety & Lock-out
Code = 1, 10 False Code/Card Lock-out 60 Sec
7 0
User Code Entry Mode
Code = 2, Manual Entry Mode
7 1
7 2
O/P Operation Announcer
7 3
Status LED Standby Flashing ON-
OFF
Code = 1, Flashing Enabled
9 0
Egress Delay & Warning
Code 1 = 0, Instant, No Delay
Code 2 = 1, Momentary Contact without Warning
Code = 1, Pacifier Tone ON
Code = 1 Sec, Notification Beep ON
Pacifier Tones ON-OFF Selection
THE DEFAULT VALUES AFTER REFRESHING
NOTE:
The DAP Code
2 8 2 8
and the Refreshing Code
9 9 9 9
are fixed in the operating system program.
It can not be changed in any ways.
NOTE:
1) Momentary Contact
-- The Egress Delay starts to count when the egress button is momentarily
2)
3)
The Egress Delay does not affect the operation of the User Codes/Cards for Output 1. The User
(4) VALIDATION
Press
key once . Two-beeps confirms the entry
EXAMPLES:
Example 1
: Set Egress Button in Momentary contact of 5 seconds with delay & warning beep
(a) (b) (c) (d)
(a)
Egress function programming,
(b)
Momentary contact with warning,
(c)
Delay time of 5 seconds
to release door, (d) Entry confirmation
Example 2:
Set Egress Button in Holding contact of 10 seconds with warning beep
(a) (b) (c) (d)
(a)
Egress function programming,
(b)
Holding contact mode with warning,
(c)
Holding time of 10
seconds to release door, (d) Entry confirmation
Example 3
: Set Egress Button in Momentary contact without delay (This is the default setting)
(a) (b) (c) (d)
(a)
Egress function programming,
(b)
Momentary contact without delay,
(c)
Release door instantly,
(d)
Entry confirmation
pressed. Output 1 activates automatically (door is released) when the delay time reaches.
Code
s/Cards always give
INSTANT
action.
Holding Contact
-- The user
MUST
hold the egress button in contact for the whole period of the
Egress Delay time until Output 1 activates. If the egress button is released before the end of the
Egress Delay, the timer will stop to count and reset.
For safety, it is necessary to put
a sticker next to the egress button
telling how to open the
door if “Holding Contact” is enabled.
Example: A sticker for an egress button that is programmed with “Holding Contact” of 5 seconds.
Press & Hold The Button
5 Seconds Minimum
Until The Door Is Open
Summary of Contents for DK-2890
Page 2: ......
Page 48: ...AEI PROTECT ON SYSTEMS LIMITED www apo hk com...