EXAMPLES – PROGRAMMING AND OPERATION
1) Example 1 -- EM Card Only :
i) Programming :
(a) (b) (c) (d) (e)
(a) The card is programmed for operating Output 1
(b) The operation is medium EM Card only
(c) Take ID number 001 in Group 1 to store the card, which is one of the IDs in 000-999
(d) Put the card close to the reader, one beep confirms the reading
(e) Press # to store the “Card”, two-beep confirms a valid entry
ii) Operation : (while the system is back to operation mode)
(a)
(a) Read the EM card. Two-beep confirms the card is read and Output 1 activates
2) Example 2 -- Private User Code Only :
i) Programming :
(a) (b) (c) (d) (e)
(a) The Private User Code is programmed for operating Output 1
(b) The operation medium is Private User Code only
(c) Take ID number 002 in Group 1 to store the Private User Code, which is one of the IDs in
000-999
(d) Put Private User Code “1 2 3 4” into the storage location
(e) Press # to store the “Private User Code”, two-beep confirms a valid entry
ii) Operation : (while the system is back to operation mode)
(a) (b)
(a) Key in the Private User Code “1 2 3 4”
(b) Confirm it with the # key. Output 1 activates
Read Card
Read Card
PERSONAL SAFETY AND SYSTEM LOCK-UP (Location 60)
(1) LOCATION
Key in Location
(2) LOCK-UP OPTIONS
The Options are represented by the following Numbers. They are described below:
--- After 10 successive false Card/User Code trials, the keypad locks during 60 seconds.
- (Default)
-
--- Selection of after 5 to 10 successive Card/User Code trials, the keypad locks during
Example:
Release the lock-up --
--- Disappearance of all the above lock-up securities.
(3) VALIDATION
Press key once . Two-beeps confirms the entry
SUPER USER CODE
1 to 2 Digits
LOCK-UP OPTIONS
VALIDATION
LOCATION
(3)
(2)
(1)
15 minutes. The keypad can be reset to release the lock-up with the “Super User
Code” in the following way.