EGRESS DELAY , WARNING AND ALARM (Location 90)
(1) LOCATION
Key in Location
(2) CONFIGURATIONS OF THE EGRESS WARNING AND ALARM
Key in the number to enable 1 of the configurations described below:
---
Momentary Contact Mode without Warning -- (Default)
---
Momentary Contact Mode with Warning Beep
---
Holding Contact Mode without Warning
---
Holding Contact Mode with Warning Beep
(3) EGRESS DELAY TIMER
---
No Delay – (Default)
Output 1 activates instantly (the door is released instantly) when the Egress Button is pressed.
–
---
Egress Delay Timing
Put a number of 1 to 99 into the box to enable the Egress Delay. The number is the time in second,
which starts to count when the Egress Button is pressed. Output 1 activates (the door is released)
when the delay time reaches.
4 to 8 Digits
MASTER CODE (Location 01)
LOCATION MASTER CODE VALIDATION
(1) LOCATION
Key in Location
(2) MASTER CODE
(3) VALIDATION
Master Code is the authorization code for setting the system to programming mode. It is
NOT
an User Code operating the output relays.
The Master Code can be 4 to 8 digits.
When a new master code is keyed in and confirmed, the old master code is replaced.
The master code is also the
Link-up Code
between the keypad and the optional decoder in
Split-decoded operation.
CONFIGURATIONS
VALIDATION
DELAY TIME
LOCATION
,
,
or
-
(2)
(1)
(3)
(2)
(4)
(3)
(1)
Press key once. Two-beeps confirms the entry.
Example:
Set a Master Code “2 2 3 3” ----
Press and hold the Button. No warning or alarm is given during the Egress Delay.
Good for the silent area. The people require to press & hold the button until the delay time
reaches for the door open.
Press and hold the Button. The system gives Warning Beeps during Egress Delay.
Good for the place required attention. The keypad beeps while the button is kept pressed during
the people are waiting for the door open.
Press the Button once. The system gives Warning Beeps during the Egress Delay.
Good for the place required attention. The keypad beeps during the people are waiting for the
door open.
Press the Button once. No warning or alarm is given during Egress Delay.
Good for silent area. The people have to wait for the door open until the delay time reaches.
SUPER USER CODE (Location 02)
The Super User Code has TWO functions. It is prepared to operate the two outputs and make
operation of inhibit enable / disable to those outputs.
(1) LOCATION
Key in Location
(2) SUPER USER CODE
The Super User Code can be 4 to 8 digits.
When a new Super User Code is keyed in and confirmed, the old one is replaced.
(3) VALIDATION
Pressing
key to confirm code entry.
Example:
a) Set a Super User Code “2 5 8 0” ----
b) Deleted a Super User Code from memory: Key in the Location number and #. ----
4 to 8 Digits
(1)
(2)
(3)
LOCATION SUPER USER CODE VALIDATION
Summary of Contents for DK-2890
Page 2: ......