Operation Modes
Close The Programming Mode
PROGRAMMING SUMMARY CHART
APPLICATION EXAMPLES
Stand Alone Door Lock
Basic Wirings of a Stand Alone Lock
APPLICATION EXPANSIONS
The Axiliary Readers & Keypad
The Split-decoders
1) Dual-station Access Control Door Lock
2) Multi-station Access Control Door Lock
3) Split-decoded Access Control Door Lock
4) Split-decoded Multi-station Access Control Door Lock
AUXILIARY INFORMATION
AUXILIARY INFORMATION
OPEN COLLECTOR
OUTPUT ----
Output switches to
ground when activated
N.O. CONTACT
OUTPUT ----
Output switches to
ground when activated
EQUIVALENT
DRY CONTACT
A dry contact means that no electricity is connected to it. It is prepared for free connections. The
Relay Output contacts provided in this keypad system are dry contacts.
N.C.
Normally Closed, the contact is closed circuit at normal status. It is open circuit when active.
N.O.
Normally Open, the contact is open circuit at normal status. It is closed circuit when active.
TRANSISTOR OPEN COLLECTOR OUTPUT
An open collector output is equivalent to a Normally Open (N.O.) contact referring to ground
similar to a relay contact referring to ground. The transistor is normally OFF, and its output
switches to ground (-) when active. The open collector can only provide switching function for
small power but it is usually good enough for controlling of an alarm system. The Duress,
Inter-lock and Key Active/Alarm Outputs of the keypad are open collector outputs.
···································································································································· 36
················································································································ 36
································································································ 37-38
···················································································································· 39
························································································································ 39
····································································································· 39
············································································································ 40-46
··············································································································· 40
·································································································································· 41
·····························································································42
·························································································· 43
························································································· 44
····································································· 45
····················································································································· 46
Summary of Contents for DK-2890
Page 2: ......
Page 48: ...AEI PROTECT ON SYSTEMS LIMITED www apo hk com...