OUTPUT MODE & TIMING FOR OUTPUT 1 & 2 (Locations 51 & 52)
The two relay outputs are programmable for Start/Stop or Timing modes. Apart from door access
control, alarm arm-disarm control, they are also
universal timers for automatic operators in
industry
with their 99,999 seconds (over 24 hours) programmable timer.
(1) LOCATIONS
-- Location for Output 1
-- Location for Output 2 (DK-2891A only)
(2) OUTPUT MODE & TIMING
Start /Stop Mode (Toggle)
The number 0 sets the output to
Start / Stop mode
. The output
Starts
when an User Code
and/or Card is entered/read; the output
Stops
when an User Code and/or Card is
entered/read again.
--
Seconds Momentary --- (Default -- Momentary 5 Seconds)
The output can be set in
Momentary Mode
with the time of 1 second to
99,999 seconds. The output will reset automatically when the time
expires.
(3) VALIDATION
Press key once. Two-beep confirms the entry.
RESET OUTPUT TIMER WITH SUPER USER CODE
The Output Timer can be
RESET manually at anytime with the Super User Code
that operates
the desired output before the end of the time.
Example:
Reset Output 1 Timer
--
-------------
Output 1 stops
Reset Output 2
Timer
--
-------------
Output 2 stops
SUPER USER CODE
SUPER USER CODE
OUTPUT MODE & TIME
VALIDATION
LOCATIONS
-
or
-
(3)
(2)
(1)
(iii) Pause the real-time inhibition manually
The real-time inhibition can be stopped temporarily if require; such as the staff work overtime in
office. The inhibition can be paused manually with Super User Code before or during the
inhibition period. The pause is toggle and does not affect the real time period counting.
---- Inhibition paused [Inhibit LED(Red) Flashing]
---- Inhibition resumes [Inhibit LED(Red) ON]
NOTE:
The “INHIBIT” LED(Red) is flashing during the paused period; and it is ON after inhibition resumes.
(iv) Open door lock with Super User Code at anytime
The Super User code is valid all the time even in the inhibition period. This function does not
affect the real time period counting.
---- The door is open
Super User Code
Super User Code
Super User Code
Programming and Operation Examples:
(i) Set the starting and stopping time for the real-time inhibition period
a) Set Inhibition Period from 12:30 PM (today) – 1:30 PM (same day) for lunch time:
b) Set Inhibition Period from 6:30 PM (today) – 8:15 AM (next day) for office close:
NOTE:
1) The start and stop time figures are 24 hours basis. They are 4-digit figures from the smallest
00:00
to the largest
23:59.
2) Entry of the two figure values from
Small
(Start) to
Large
(Stop) for the period of inhibition; the
inhibition will start and stop in the same day. See
example (a)
.
3) Entry of the two figure values from
Large
(Start) to
Small
(Stop) for the period of inhibition; the
inhibition will start at the time of the day; thus stop in the next day. See
example (b)
.
4) The keypad does not accept the “Start” and “Stop” times with same value. The two time figures
must be different.
(ii) Clear the function of inhibition
Clear the time settings to stop the function of inhibition: