Auto Entry Mode requires no pressing of the # key after code entry for code checking.
In the Auto Entry Mode, the
User Codes MUST be set in the same digit length of the
Master Code
(For example, if the Master Code is 5 digits, then all User Codes must be in 5
digits as well. All other User Codes not in 5 digits become invalid). When the number of digits
reaches, the system will check the User Code automatically. Good for high traffic access control.
USER CODE ENTRY MODE – Auto or Manual (Location 70)
(1) LOCATION
Key in Location
(2) USER CODE ENTRY MODES
Two modes 1 and 2 are available for User Code entry options. The
EM Card is always in Auto
Entry Mode
and is not affected by the selection here.
---
Auto Entry Mode
---
Manual Entry Mode – (Default)
(3) VALIDATION
Press
key once. Two-beep confirms the entry
PACIFIER TONES ON-OFF SELECTION (Location 71)
(1) LOCATION
Key in Location
(2) FUNCTION MODES FOR PACIFIER TONES
Pacifier Tone is the Beep Tones from the keypad, which include the tones of Successful Key entry
(1 beep) and the Unsuccessful User Code/Card entry (5 beeps).
NOTE:
The beeps for the Warning and the Power-up Delay do not belong to pacifier tones and can not be
OFF.
---
Pacifier Tone ON – (Default)
---
Pacifier Tone OFF
(3) VALIDATION
Press key once. Two-beep confirms the entry
All the Pacifier Tones available from the keypad are enabled. They are the response tones
indicating the operation status of the keypad after a Card/User Code is entered.
All the Pacifier Tones are OFF. Good for place needs for a silent environment.
VALIDATION
LOCATION
or
ENTRY MODES
(2)
(3)
(1)
FUNCTION MODES
VALIDATION
LOCATION
or
(2)
(3)
(1)
VISITOR CODES (FOR OUTPUT 1 ONLY) (Location 40)
The Visitor Codes are temporary user codes for Output 1 (mainly for door strike in access control).
They can be programmed as
“One Time Codes”
or
“Codes with Time Limit”
. The Visitor Codes
will be cleared automatically after use if they are one time codes, or, when the allowed time
expires.
(1) LOCATION
Key in Location
(2) VISITOR ID
--- 50 Visitor IDs for the 50 visitor codes. They are Two-digit numbers
=
(3) VALID PERIOD
The codes in this box
MUST
be two digits and they represent the time of operation.
--- One Time Code
One Time Code has no time limit but it can only be used for ONCE. It is cleared by the
system automatically after use.
- --- Time Limit in Hour(s)
(4) VISITOR CODES
NOTE: All Visitor Codes will be cleared after power down to prevent extension/confusion of
their valid time limit.
(5) VALIDATION
Press key once. Two-beep confirms the entry.
The Visitor Code can be set with the valid time limit of 1 Hour to 99 Hours with
a two-digit number of 01 to 99. The visitor code is cleared by the system when
the time limit reaches.
4-8 DIGITS
-
or
-
VISITOR CODE
VALIDATION
LOCATION
VISITOR ID
VALID PERIOD
(5)
(4)
(3)
(2)
(1)
-
Clear all the Visitor Codes in Location 40. Please see the Programming example
below for the details.
The Visitor Codes can be 4-8 digits for Manual Mode code entry.
The Visitor Codes MUST be in the same digit length with the Master Code for Auto Mode code
entry.
When a new Visitor Code is put in the same Code box, the old code is replaced.
Manual Entry Mode always requires the # key following the User Code for code checking.
The User Codes can be
4-8 digits arbitrary
and they are
NOT
required to be in the same
digit length of the Master Code. Manual Entry increases the level of security in code trial by
the unauthorized people.
Summary of Contents for DK-2891A
Page 2: ......
Page 52: ...AEI PROTECT ON SYSTEMS LIMITED www apo hk com...