PROGRAMMING MAKE SIMPLE – For General Users
The DK-2891 is a multi purpose keypad. It has many functions for user’s selection. For those general
users taking the keypad for door strike only, most of the features can be kept in their Default values.
Only the User Codes / Cards and a private Master Code are required to program.
The keypad accepts
1) Card only, 2) Code only, 3) Card + Code or 4) Card + Common User
Code
to operate its outputs.
PROGRAMMING
NOTE:
a) The button is equivalent to the button in the keypad with bell button.
b) Wait 1 minute until the end of power up delay, or keyin
to stop the power-up delay
instantly and set the keypad to normal operation.
1) Set System in Programming Mode with The Factory Set Master Code 0 0 0 0
---- 2 beeps, system is in Programming Mode
Note:
If the Master Code is forgotten, use the DAP Code to set the system into programming mode.
See
DAP CODE 2828 in page
13
for the details.
2) Change The Factory Set Master Code to Owner’s Private Master Code for Security
Reason
----
3) Record an “EM Card” to Operate The Output 1 for Door Open
(a) (b) (c) (d) (e)
(a) 10 = Programming Location for Output 1
(b) 1 = Programming option for EM Card only
(c) 001 = One of the 1,000 User IDs for the User Code/Card from 000-999
(d) Read Card = Put the Card close to the card reader
(e) # = Confirm the card is read, 2 beeps
4) Set an “User Code” to Operate The Output 1 for Door Open
(a) (b) (c) (d) (e)
(a) 10 = Programming Location for Output 1
(b) 2 = Programming option for User Code only
(c) 002 = One of the 1,000 User IDs for the User Code/Card from 000-999
(d) 8321 = The User Code for door open. It is for example here only
(e) # = Confirm the User Code, 2 beeps
READ CARD
2 beeps, 3 2 8 9 is a Master Code for example here only.
It replaces the old master code 0000.
OPERATION AND FUNCTIONS OF THE SUPER USER CODE
1) Operate Output 1 and 2
The operation of the Super User Code is just like a normal User Code. Simply key-in the Code with a
specific output number for the desired Output. The Super User Code can also be used to reset an
operating output timer instantly.
---------- Output 1 Activates or Resets
---------- Output 2 Activates or Resets
Optional Functions Controlled by Super User Code for Output 1
Apart from controlling of the three outputs 1 and 2; the Super User Code can also be used to enable
the optional functions controlling
Output 1
for user convenience or security enhancement.
Super User Code and Egress Button are excluded from any system inhibition and lockup functions;
they are valid for door open at anytime for safety.
2) Override The Door Lock Controlled by Output 1 (Keep Door Un-locked)
The Output 1 is usually for door lock control. In some situations, the door may require un-locked for
a period of time to allow door opening without User Code or EM Card for entry / exit convenience.
This function Starts / Stops in toggle with the following code entry.
---------- The Door is Un-locked, Start / Stop in Toggle
NOTE :
•
•
•
•
3) Pause The Scheduled Daily Inhibition for Output 1 (Temporarily Disable The Inhibition)
The scheduled inhibition can be programmed and applied to Output 1 with daily start and stop times.
It can be stopped temporarily if required; such as the staff work overtime after office hours going
into the inhibition period. This function Starts / Stops in toggle with the following code entry. It can
be done before or during the inhibition period.
---------- Door Lock Operation Resumes, Start / Stop in Toggle
NOTE :
•
The “INHIBIT” LED (Red) is ON in inhibition and turns to Flashing while pause is into effect.
•
See
Programming Locations 55 & 56
for more information Daily Inhibition.
SUPER USER CODE
SUPER USER CODE
SUPER USER CODE
SUPER USER CODE
The door is un-locked while the function is enabled. The “Output 1” LED (Green) turns ON.
Do not
forget to stop this function after use because the door is un-locked. Also, the system
refuses the optional functions (3) & (4) while Override function comes into effect.
This feature is
good for all the “Fail-safe electric locks”.
“Fail-secure electric lock”
requires power to keep in un-locked condition. It takes high current
all the time while the function comes into effect and
may cause damage
to it. This function is not
recommended for Fail-secure electric lock.