For example:

NOTE:

f)

Example:

g)

8321

0321

11223

31223

33221

53221

To command the Duress Function, enter the Duress Code(s).

The Duress Code(s) has double actions. It activates the Duress Output and at the same time activates

the Output 1 as like the normal User Codes in Group 1. The Duress Code(s) can always activate or

deactivate (in Start / Stop mode) Output 1, but cannot deactivate (reset) the Duress Output. ONLY the

User Codes in Group 1 can deactivate (reset) the Duress Output.

The Accelerated Code is the First Two Digits of the User code(s). If the Output has been programmed in

Start / Stop mode with Accelerated Code (Programming Option 42 for user codes in Group 1 and

Programming Option 52 for user codes in Group 2), it is possible to activate the Output with only the

First Two Digits of the User Code(s). Deactivating of the Output always requires the composition of the

Complete User Code(s) in their code Group.

Output 1 has been re-programmed to Start / Stop Mode with Accelerated Code (Programming Option 42)

with the Complete Code of 1st User Code in Group 1:

The Accelerated Code is:

2nd User Code in Group 1:

The Accelerated Code is:

Try to put some random false codes to the keypad to test its Safety. The keypad generates 5 beeps for

each unsuccessful code entry. The keypad locks itself during 15 minutes after 10 successive false codes

are entered. Normal operation will resume after 15 minutes expired, or, it can be reset with the Master

Code during the locking period.

The User Codes in Group 1

The Corresponding Duress Codes

----- Duress output activates (output switches to ground) & Output 1 activates for 1 second

-- Duress output activates (output switches to ground) & Output 1 activates for 1 second
-- Duress output activates (output switches to ground) & Output 1 activates for 1 second

------------- Output 1 starts

------ Output 1 stops

------------- Output 1 starts

--- Output 1 stops

------ Locking is reset and keypad resumes normal operation

If you want to delete User Number 3 in Group 2, press
If you want to delete User Number 2 in Group 3, press

0321 #

31223 #

53221 #

83 #

8321 #

11 #

11223 #

3289 #

2 3 #

3 2 #

8321

83

11223

11

D) DELETE USER (MULTI-USER MODE)

If you need to delete a user who has left the company or who no longer has authority to enter the protected area:

Set system in programming mode with the Personal Master Code and the

key

Enter the User Number (00-99 for output 1; 0-9 for output 2 & 3) and the

key to delete a user code

You may delete other user code(s) in this fashion

Exit the programming mode by pressing the

key after the work is done

1)

2)

3)

4)

*

3289 *

#

1 05 #

*

------------- The keypad is now in the programming mode

If you want to delete User Number 05 in Group 1, press

9

c)

d)

After the keypad is in programming mode, you may go to any Location for your programming options one by

one, please see Programming Options Summary Chart for the feature details.

You may make continuous programming until all desired options are programmed. Repeated programming at

the same Location is allowed if the previous entry was mistaken.

LOCATION 1

OPTION

LOCATION n

OPTION n

#

I

I

#

*

*

2 6854 #

3 9270 #

51 #

61 #

6854

9270

e)

1) Re uirement

3) Operate The Keypad

Exit programming mode with the

key after all your required options are programmed. The new information

that you have just programmed is saved.

a ) Single User Mode Operation
b) Change the factory-set Master Code 0000 to a Personal Master Code 3289
c) Set User Code 1 of 8321
d) Set User Code 2 of 6854
e ) Set User Code 3 of 9270
f ) Set Output 1 to Momentary Mode, 1 second
g) Set Output 2 to Start / Stop Mode
h) Set Output 3 to Start / Stop Mode
i ) Set the keypad to lock itself during 15 minutes after 10 successive false codes

-- Taking the data programmed above and other features in default value as reference

-- 6854 has been stored as User Code 2, for output 2
-- 9270 has been stored as User Code 3, for output 3

-------------- Output 2 has been set to Start / Stop Mode
-------------- Output 3 has been set to Start / Stop Mode

data

----------- Output 2 starts or stops
----------- Output 3 starts or stops

2) Programming

NOTE:

a)

-- Set the above requirement into the keypad:

a) **Enter the Single User Mode Command Code "8900" may not be necessary if the keypad was

already in Single User Mode.

b) In case of wrong entry during programming, cancel it with

key, or, wait 10 seconds, then re-try.

To command an output, only enter its user code. Press

is NOT required.

0000 *

8900 #

0 3289 #

1 8321 #

40 1 #

72 10 #

*

#

#

8321

------- System has been set in programming mode with the factory-set Master Code
------- System has been set for Single User Mode** (please see NOTE (a) below)

-- 3289 has been stored as the new Personal Master Code

Super User Code

-- 8321 has been stored as User Code 1, with Duress Code function, for output 1

--------- Output 1 has been set to Momentary Mode, 1 second

----- The keypad has been set to lock during 15 minutes after 10 successive false codes

----------------------- Keypad exits programming mode. All the above

are stored and ready for use

----------- Output 1 activates for 1 second

&

B) SINGLE USER MODE OPERATION

-- An Example

q

Summary of Contents for DK-9523

Page 1: ...of an alarm system The Duress Inter lock Key Active Outputs of the keypad are open collector output OPEN COLLECTOR OUTPUT Output switches to ground when activates N O CONTACT OUTPUT Output switches t...

Page 2: ...OUTPUT 2 1 Amp relay WHITE ORANGE DURESS OUTPUT YELLOW GREEN GND BROWN INTERLOCK CONTROL ORANGE OUTPUT 1 INHIBIT WHITE RED OUTPUT 3 OUTPUT 2 RELAY PURPLE N C YELLOW LIGHT BLUE GREEN GREY BLACK RED RED...

Page 3: ...if it is not used Connect to 12 24V AC or DC power supply The supply and GND wire 15 are the common grounding points of the keypad system No selection jumper is required for the full input voltage ran...

Page 4: ...lamp changes to steady Red while the auxiliary Red LED is energized The built in buzzer and the green LED indicator at the centre give the following tones and signals for operation status All Pacifier...

Page 5: ...quired to apply the following procedures precisely Disconnect power supply Displace the DAP jumper from OFF to ON position Reconnect power supply buzzer is activated Put the DAP jumper back to OFF pos...

Page 6: ...g Installer Programming NOTE Locations Code of Duration Locations No of False Entry Validation Comments Validation Comments Locations Code of Functions Validation Comments Locations Code of Functions...

Page 7: ...is always set with Auto Code Entry in default The user does not require to press the key in user code entry The user only needs to enter the 4 digit user code The relay will activate for the programm...

Page 8: ...ressed Multi User Mode on Duty please wait 2 3 seconds until the confirmation beeps are heard after the key is pressed SET THE SYSTEM TO SINGLE USER MODE SET THE SYSTEM TO MULTI USER MODE REFRESH THE...

Page 9: ...for output 2 3 and the key to delete a user code You may delete other user code s in this fashion Exit the programming mode by pressing the key after the work is done 1 2 3 4 3289 1 05 The keypad is...

Page 10: ...Code of The Accelerated Code will be Duress output activates output switches to ground Output 1 activates for 1 second Output 1 starts Output 1 stops 0321 83 8321 8321 83 C MULTI USER MODE OPERATION...