34
The “lamp“ of the display field will be color-coded corresponding to the calculated heat index.
keine Beeinträchtigung
Hitze-Index < 27 °C
Vorsicht
27 °C < Hitze-
Index ≤
32 °C
Erhöhte Vorsicht
32 °C < Hitze-
Index ≤
40 °C
Gefahr
40 °C < Hitze-
Index ≤
54 °C
Erhöhte Gefahr
Hitze-Index > 54 °C
Humidex
The Humidex can be set instead of the heat index as an alternative option.
The “lamp“ of the display field will be color-coded corresponding to the calculated humidex.
keine Beeinträchtigung
Humidex < 30 °C
Leichtes Unbehagen
30 °C <
Humidex ≤
39 °C
Starkes Unbehagen
39 °C <
Humidex ≤
45 °C
Starkes Unwohlsein
45 °C <
Humidex ≤
54 °C
Sehr ernste Gefahr
Humidex > 54 °C
Remark:
The heat index or the Humidex are relevant for temperatures ≥20
°C.
Remark:
The heat index or the Humidex can just be calculated if there is the measured relative
humidity.
Remark:
At temperatures
≤10
°C the wind chill will be calculated and displayed.
Wind chill
The wind chill describes the difference between the measured air temperature and the felt temperature
depending on the wind speed. It is defined for temperatures below approx. 10 °C.
The “lamp“ of the display field will be color-coded corresponding to the calculated windchill.
Windchill > -28 °C
Windchill ≤
-28 °C
à
es besteht die Möglichkeit,
dass es innerhalb von 30 Minuten
oder weniger zu Erfrierungen kommt.
For temperatures below 20 °C and above 10 °C the “lamp” is deactivated (black) and the current tem-
perature will be displayed.
In the indicator element a respective headline will be shown in dependency of the displayed value.
At
temperatures ≥20
°C
à
headline = heat index (or Humidex depending on the configuration)
temperatures below 20 °C or above 10 °C
à
headline = air temperature
temperaturen ≤10
°C
à
headline = wind chill
Remark:
The wind chill can be calculated based on available measured wind speed.
If there is no relative humidity the “current temperature” will be displayed instead of the heat index/Hu-
midex and the headline will be changed into “air temperature”. This also applies if there is no wind
speed, and the wind chill can’t be calculated.