5.1. Talker-Sensors
The talker programs clearly identify the parameter of the connected LAMBRECHT sensors. The recog-
nised telegrams will be chosen (or placed) automatically in the configuration of the COM interfaces.
The unit, the number of the decimal places, the sensor type, the mean value or the trend time will be
created correspondingly the following table. Possible virtual values which can be the result of the rec-
ognised parameter are also listed in the table.
Table of the auto configurations at known NMEA telegrams
Proto-
col
Parameter
Unit
Deci-
mal-
places
Sen-
sor-
type
Mean
value
time
Trend
time
Virtual value
WIMWV
Wind speed
m/s
0,0
G
10 Min.
---
Vectorial connec-
tion with wind di-
rection in the
same protocol
Wind chill with
temperature on
the same COM-in-
terface
Wind direction
°
0
R
10 Min. ---
Vectorial connec-
tion with wind
speed in the same
protocol
WIMTA
Temperature
°C
0,0
T
---
1 hour
Heat index with
rel. humidity on
the COM-inter-
faces
Wind chill with
wind speed on the
same COM-inter-
faces
WIMHU
Rel. air humidity
% rF 0,0
H
---
1 hour
Heat index with
temperature on
the same COM-in-
terfaces
Dew point
°C
0,0
D
---
---
WIMMB
Air pressure
hPa
0,0
P
---
3 hours
WIXDR
(PR)
Amount of precipita-
tion
mm
0,0
N
---
---
WIXDR
(C/H/P)
Temperature
°C
0,0
T
---
1 hour
Heat index with
rel. humidity on
the same COM-in-
terfaces
Wind chill with
wind speed on the
same COM-inter-
faces
Rel. air humidity
% rF 0,0
H
---
1 hour
Heat index with
temperature on
the same COM-in-
terfaces
Dew point
°C
0,0
D
---
---
Air pressure
hPa
0,0
P
---
3 hours