Operating Instructions 

Combined Wind Sensor ARCO SDI-12

(14582) ARCO SDI-12

Operating Instructions

Syntax for measurements with command "aC!" or "aM!"

Command 

 

 

 

 

Answer

aD0! 

     a<values><CR><LF>

 

a

 – Sensor address 

 

 

 

a

 – Sensor address

 

D

 – Command ‘Send Data’ 

 

 

<values>

 – Requested data separated by

 

0

 – Request for the data in buffer 0 

 

 

       resp. sign ("

+

" or "

-

")

 

      or 

 

      

1

 = buffer 1

 

!

 – End of command 

 

 

 

<CR><LF>

 – End of answer

Example:

Command 

 

Answer

0C! 

  000004<CR><LF>

0D0! 

  0+0.1+0.1+0.1+0.1<CR><LF>

Syntax for measurements with command "aCC!" or "aMC!"

Command 

 

 

 

 

Answer

aD0! 

     a<values><CRC><CR><LF>

 

a

 – Sensor address 

 

 

 

a

 – Sensor address

 

D

 – Command ‘Send Data’ 

 

 

<values>

 – Requested data separated by

 

0 – Request for the data in buffer 0 

 

 

       resp sign ("

+

" or "

-

")

 

      or

 

      

1

 = buffer 1   

 

 

 

<CRC>

 – 3-digit CRC checksum

 

!

 – End of command 

 

 

 

<CR><LF>

 – End of answer

Reset addresses - aX!

If inadvertently the same address has been assigned to wind direction and wind speed, the sensor can be reset 

to address 0 for wind speed and address 1 for wind direction with the command "

aX!

".

13

Summary of Contents for LAMBRECHT meteo ARCO SDI-12

Page 1: ...and special alloys Corrosion resistant surfaces for long service life Particularly low starting value 0 3 m s Measuring range from 0 3 55 m s Quick and easy installation thanks to pipe mounting and M...

Page 2: ...2 5 Mounting the cup rotor 4 2 6 Mounting the wind vane 4 2 7 Installation procedure brief description 4 2 7 1 Mounting the sensor 4 2 7 2 Power supply and signal cables 5 2 7 3 Safety regulations 5 3...

Page 3: ...speaking they apply only to the location where the measuring instrument is installed Therefore special attention should be paid to the choice of installation location For wind measurements according t...

Page 4: ...50 mm and an inside diameter of at least 40 mm Before attaching the instrument with the two grub screws M8 x 12 connect the cable lead it through the pipe and align the sensor to the north For this pu...

Page 5: ...ety regulations must be followed dur ing installation During the electrical installation work the relevant circuits must be disconnected from the power supply The housing must only be opened by author...

Page 6: ...Operating Instructions Combined Wind Sensor ARCO SDI 12 14582 ARCO SDI 12 Operating Instructions 5 Dimensioned drawing ARCO SDI 12 6...

Page 7: ...Operating Instructions Combined Wind Sensor ARCO SDI 12 14582 ARCO SDI 12 Operating Instructions 6 Electrical connection ARCO SDI 12 7...

Page 8: ...CR LF aMC Start Measurement and Request CRC atttn CR LF aC Start Concurrent Measurement atttnn CR LF aCC Start Concurrent Measurement and Request CRC checksum atttnn CR LF aD0 Send Data Buffer 0 a dat...

Page 9: ...speed 14582D Wind direction 1 1 Firmware version End of command CR LF End of answer Example Command Answer 0I 014LMGmbH1514582S1 1 CR LF 1I 114LMGmbH1514582D1 1 CR LF Change address aAb The factory se...

Page 10: ...always responds with a000 The data is therefore immediately available This is also the reason why the ARCO SDI 12 does not send a service request and ignores measurement inter ruption commands The da...

Page 11: ...ly with multiple sensors on the same bus The aC command requests the sensor to process the available measurement data and write them to an output string Unlike the standard sensors described in the SD...

Page 12: ...mmand Answer 1CC 100004 CR LF Send Data aD0 The data requested by the sensor with the commands C or M can be retrieved with the command aD0 The sensor uses the corresponding signs or as field separato...

Page 13: ...e Command Answer 0C 000004 CR LF 0D0 0 0 1 0 1 0 1 0 1 CR LF Syntax for measurements with command aCC or aMC Command Answer aD0 a values CRC CR LF a Sensor address a Sensor address D Command Send Data...

Page 14: ...onents require express written permission from LAMBRECHT meteo GmbH These activities must be performed by a qualified technician The warranty does not cover 1 Mechanical damage caused by external impa...

Reviews: