12
Clamp-on Meter Models 501 and 503
Over Load:
displayed when input signal exceeds range
Sample Rate:
2 samples/sec for the digital display
20 samples/sec for the analog bargraph
Power Supply:
Two 1.5V AAA (LR03) batteries
Low Power Indication:
displayed when the battery
is below the required voltage
Battery Life:
100 hours approx (Model 501)
80 hours approx (Model 503)
Auto Power Off:
The meter will shut itself OFF if there
is no activity for 30 minutes.
Jaw Opening:
1.1" (28mm)
Dimension
(L x W x D):
7.60 x 1.97 x1.1" (193 x 50 x 28mm)
Weight:
8.11 oz (230g) with batteries
3.3 Environmental Specifications
Operating Temperature:
32° to 104°F (0° to 40°C), <80% RH, non-condensing
Storage Temperature:
14° to 140°F (-10° to 60°C), <70% RH, battery removed
Altitude:
2000m
3.4 Safety Specifications
EN 61010, 600V, CAT II
EN 61010, 300V, CAT III
Pollution Degree:
2
www.
ShopAEMC
.com
Shop for AEMC products online at:
1.888.610.7664