3.4.2 Stopping a Recording Session
1.
Press and hold the
CONTROL
button. When the STOP (AMBER) LED
lights up, release the button.
2.
The GREEN LED will change from a double-blink to a single-blink,
indicating STANDBY mode.
The data will be retained, even if the instrument is in SLEEP mode. The
recorded data is stored in Flash memory (maintained even in the absence
of batteries). The recorded data may be downloaded to a computer.
3.5 Downloading Recorded Data
Recorded measurements stored in the instrument are transferred to a
computer via the download command in the
Simple
Logger
II
Control
Panel.
3.6
Clearing Alarm Indication
Clearing alarms can be performed in the
STANDBY
or
RECORD
mode.
1.
Press and hold the
CONTROL
button. When the ALARM (YELLOW)
LED lights up, release the button. The YELLOW LED will blink at a fast
rate for a period of five seconds
2.
Press the
CONTROL
button for another 0.5 second to complete the
operation.
This does not clear any stored alarms, only indications. Stored alarms can
only be cleared when memory is erased (see
§
3.7 -
Erasing Data from
Memory
).