9

A

AC/DC

40mA

400mA

10A 

(1)

Voltage

450mV

650mV

400mV

drop 

(2)

Digital

10µA

100µA

10mA

resolution

Bargraph

1mA

10mA

1A

resolution

Accuracy

± 0.8% of Reading ± 2cts

±1.2% R

on DC

± 4cts

Accuracy 

(3)

± 1.2% of Reading ± 4cts

± 1.5% R

on AC

±  5cts

Protection 

(4)

 Fuse 0.5A HBC

 Fuse 12A HBC

(1) Crest factor FC 

 3

(2) Voltage drop at the terminals for 40mA, 400mA, 10A
(3) Use on frequency: 40Hz to 1000Hz
(4) Permitted overloads: 12A for 30 seconds for the 10A rang

e

9 - GENERAL SPECIFICATIONS

9-1

Dimensions and Weight

2.5 x 7 x 1.7 " (64 x 177 x 42mm)

12.3 ounces (350g)

9-2

Power Supply

One battery 9V
Battery life: 300h with battery type 6 F 22

500 h with alkaline battery type 6 LF22

Low battery indication: 

+

-

Auto off after 30 minutes

    

Note:

 Switch on again via the OFF position.

9.3

Buzzer

Continuous beep for the continuity test
Intermittent beep each time the switch or buttons are pressed,
and for the overload indication.

9-4

Climatic conditions

Temperature: use: 0°C to +50°C / storage : -20°C to +60°C
Relative humidity: use: 

 70% RH

storage: 

 90% RH (up to 45°C)

Altitude: use <2000m

9-5

Conformity with International Standards

9-5-1

Electrical Safety (IEC 1010-1)

Double insulation:

 Installation category: III

Degree of pollution: 2

 Assigned voltage: 600VRMS

Note:

 This multimeter, of overvoltage category III satisfies the severe

requirements of reliability and availability corresponding to industrial
and domestic permanent installations (IEC 664-1).

Summary of Contents for C.A 5230

Page 1: ...r manual DigitalMultimeter Model C A 5230 MULTIMETER Hz V V OFF mA 10A M I N MAX RANGE HOLD ZERO 10A 500mA FUSED 10A max FUSED C A 5230 COM 600V CAT III MAX ZERO n u F Mk Hz HOLD 30 20 10 0 40 RMS MUL...

Page 2: ...instrument and invalidation of the warranty Fuse 0 5A HBC 500V min 10kA 6 3 x 32mm Fuse 12A HBC 600V min 300kA 10 3 x 38mm Never use on voltage to earth circuits above 600V with a voltage surge categ...

Page 3: ...rofessionals in electricity true rms measurement RMS digital 4000 counts and 42 segment bargraph automatic or manual range selection auto off after 30 minutes without action on a control or function p...

Page 4: ...measurement HOLD On capacitancemeter function zero reset by press without releasing Permanent operation possibility of suppressing auto off by pressing this button without releasing before operating...

Page 5: ...lead for the 10AAC DC ranges 3 DC AND AC VOLTAGE Connect the leads to the multimeter and connect it in parallel to the circuit to be tested Place the selector switch on the voltmeter function VAC DC A...

Page 6: ...tton for this function selects the triggering threshold 10mV for 100Hz 1kHz and 10kHz ranges 400mV for 100kHz and 400kHz ranges 2 Note Ifthefrequencyappliedis99 99kHz thedecimalpointoscillatesbetween9...

Page 7: ...Connect the leads to the multimeter and to the terminals of the component to be tested Place the selector switch on the function in forward direction the display gives the value of the junction in vo...

Page 8: ...ges manually MIN MAX to read the min or max values to light the display 4nF 40nF 400nF 4 F 40 F 1 Resolution 1pF 10pF 100pF 1nF 10nF Accuracy 2 R 150cts 2 of reading 8cts Protection 500V mns 750 peak...

Page 9: ...6 F 22 500 h with alkaline battery type 6 LF22 Low battery indication Auto off after 30 minutes Note Switch on again via the OFF position 9 3 Buzzer Continuous beep for the continuity test Intermitte...

Page 10: ...el MR410 400AAC 600ADC Cat 1200 70 AmpFLEX model 1000 24 1 1 1000AAC Cat 2112 39 Replacement leads Cat 2118 66 Soft carrying case Cat 2118 65 Replacement shockproof case Cat 2980 15 Fuse set of 10 0 5...

Page 11: ...our factory service center at one year intervals for recalibration or as required by other standards For instrument repair and or calibration please call our factory toll free at 800 945 AEMC 800 945...

Reviews: