9-5-2 Electromagnetic compatibility: conforms to CE

!

Emission (EN 50081-1)       

!

Immunity (EN 50082-1)

9-5-3 Mechanical protection

!

Degree of watertightness (IEC 529) : protection index IP 40

10 - TO ORDER

Use designations and references below

C.A 5240 ....................................................................... Cat# 2116.77
Sold with shockproof case, a pair of leads with probes attached,
a 9 V battery and this user’s manual
Accessories

!

AC current probe model MN 251 (200 A AC) ........... Cat# 2115.77

!

AC current probe model MD 303 (500 A AC) ........... Cat# 1201.21

!

AC current probe model SR 652 (1000 A AC) .......... Cat# 2113.46

!

AC/DC MicroProbe model K110

(from 100 µA AC/DC to 300 mA AC/ 450 mA DC) ....... Cat# 2111.73

!

AC/DC current probe model MR410

(400 A AC/600 A DC) ................................................... Cat# 1200.70

!

AmpFLEX model 1000-24-1-1 (1000 A AC) ............. Cat# 2112.39

!

Replacement leads ................................................... Cat# 2118.66

!

Soft carrying case ..................................................... Cat# 2118.65

!

Replacement shockproof case .................................. Cat# 2980.15

!

Fuse set of 10, 0.5 A ................................................. Cat# 2970.28

!

Fuse set of 10, 12 A .................................................. Cat# 2970.21

11 - WARRANTY

Our guarantee is applicable for three years after the date on which
the equipment is made available (copy available on request).

12 - MAINTENANCE

For maintenance, use only specified spare parts.
The manufacturer will not be held responsible for any
accident occurring following a repair done other than by its
After Sales Service or approved repairers.

12-1 Replacement of battery and fuses

  The multimeter must be disconnected from any electrical

source.

!

Put the switch in the OFF position

!

Unscrew the captive screws and remove the lower half of the casing

!

Replace the worn battery with a 9 V battery (6F22 or 6LF22)

Summary of Contents for C.A 5240

Page 1: ...SH User manual Digital Multimeter Model C A 5240 MULTIMETER Hz V V OFF mA 10A M I N MAX RANGE HOLD PEAK 10A 500mA FUSED 10 A max FUSED C A 5240 COM 600V CAT III PEAK V HOLD 30 20 10 0 40 TRUE RMS MULT...

Page 2: ...instrument may be damaged and the warranty cancelled 0 5 A HBC fuse rapid F 500 V min 10 kA 6 3 x 32 mm 12 A HBC fuse gR 600 V min 300 kA 10 3 x 38 mm Never use on voltage to earth circuits above 600...

Page 3: ...s of electricity professionals true RMS measurement 40 000 count digital display and 40 segment bargraph automatic or manual selection of measurement stops automatically after 30 minutes if a command...

Page 4: ...rement HOLD is displayed MIN MAX PEAK To display minimum and maximum values one after the other The instrument goes into manual measurement selection Hold this button down to switch to PEAK mode 1 ms...

Page 5: ...er V or V position Automatic measurement selection read off the value measured Save the value if necessary by pressing on the HOLD button If necessary press on the following buttons RANGE to select th...

Page 6: ...rms and 750 V peak overload Operating 1 at 500 V range 1 1 Trigger threshold 500 mV from 1 Hz to 100 kHz 1 5 V from 100 kHz to 500 kHz 5 CONTINUITY AND RESISTANCE Never test a resistance on a live cir...

Page 7: ...lug the leads into the multimeter and connect to the terminals of the component to be tested Put the switch in the function in the direct direction the display gives the value of the junction in volts...

Page 8: ...the display 4 nF 40 nF 400 nF 4 F 40 F 1 Resolution 1 pF 10 pF 100 pF 1 nF 10 nF Accuracy 3 rdg 20 ct 1 5 rdg 5 cts 2 R 5 ct Protection 500 V rms and 750 V peak 1 For a capacitance C 20 F the accuracy...

Page 9: ...battery 9 V Autonomy 200 hrs with type 6 F22 battery 400 hrs with alkaline type 6 LF 22 battery Indication of battery wear Automatic cut out after 30 minutes Note Restart from the OFF position 9 3 Bu...

Page 10: ...Cat 1200 70 AmpFLEX model 1000 24 1 1 1000 A AC Cat 2112 39 Replacement leads Cat 2118 66 Soft carrying case Cat 2118 65 Replacement shockproof case Cat 2980 15 Fuse set of 10 0 5 A Cat 2970 28 Fuse...

Page 11: ...at one year intervals for recalibration or as required by other standards For instrument repair and or calibration please call our factory toll free at 800 945 AEMC 800 945 2362 CHAUVIN ARNOUX Inc d b...

Reviews: