Fault Mapper Model CA7024
9
4.3
Getting Started
The instrument is switched on and off using the green power button
,
found on the lower right side of the front panel.
When the unit is first switched on it will display the opening screen giving
the software version, the currently selected cable type/Velocity of Propa
-
gation, and remaining battery capacity.
AEMC Instruments
Fault Mapper V3.1B
Romex 14/2
Vp=66%
4.4
Set-up Mode
Hold the
TDR /
button, then press the
TEST /
button to enter Set-up mode.
Feet
Eng (USA)
Edit Library
Contrast
>
• Measurement units can be set to Feet or Meters
• Languages can be set to: English, Français, Deutsch, Español or
Italiano
• A user programmable library is available to store up to 15 custom
-
ized settings
• The display contrast can adjusted
Press the
TEST /
button to move the line selector (
>
) down the screen.
Press the
Vp
or
Vp
button to change the setting of the line selected.
Press the
TDR /
button again to save changes and exit set-up mode.
NOTE:
When the Fault Mapper is turned off, it will remember the
current set-up parameters. This feature is useful in the situation
where the operator is performing many tests on the same type of
cable.
www.
.com
information@itm.com
1.800.561.8187