background image

ELECTRICAL SPECIFICATIONS

 

Nominal Range: 

10A

 

Measurement Range: 

0.1 to 12A 

Transformation Ratio: 

Voltage output

 

Output Signal: 

100mV/A (1V at 10A) 

Accuracy and Phase Shift*: 

Accuracy: 

0.1 to 0.5A: 

 2.5% Reading ± 0.1mV 

0.5 to 1A: 

 2.5% Reading 

1 to 12A:  

 1% Reading 

Phase Shift: 

.01 to 0.1A:  Not Specified 
0.1 to 1A: 

 5° 

1 to 5A: 

 3° 

5 to 12A:  

 2.5° 

*Reference conditions: 20°C to 26°C, 20 to 75% RH,
external magnetic field <40A/m, 48 to 65Hz sine wave,
distortion factor less than 1%, no DC component, no
external current carrying conductor, test sample centered. 
Load impedance > 1M

Frequency Range: 

40 to 10kHz

 

Limit Operating Conditions: 

20A permanently to 10kHz; 
Derating above 10kHz: 20A x 0.1F (in kHz) 

Crest Factor: 

3 @ 10Arms with an error (due to CF) of 3% 

Working Voltage: 

600Vrms 

Common Mode Voltage: 

600Vrms 

Influence of Adjacent Conductor: 

< 15mA/A at 50Hz 

Influence of DC on AC signal: 

DC Current < 2A, < 5% 

Influence of Conductor Position in Jaw:  

0.5% of mV output @ 50/60Hz 

Influence of Frequency:

40Hz to 1kHz: 0.5% of mV output 
1kHz to 10kHz: 2% of mV output 

Influence of Temperature: 

 150ppm/°K, or 0.15% of mV output per 10°K 

Influence of Humidity (10 - 90% RH): 

 0.2% of mV output per 10°K @ 18° to 28°C 

MECHANICAL SPECIFICATIONS 

Operating Temperature: 

14° to 131°F (-10° to +55°C)  

Storage Temperature: 

-40° to 158°F (-40° to +70°C) 

Operating Relative Humidity: 

10° to 35°C 85% RH 
(without roll-off above 35°C) 

Maximum Cable Diameter: 

One Ø 0.78" (20mm), bus bar 20 x 5mm 

Case Protection: 

IP 40 (IEC 529) 

Drop Test: 

Test per IEC 68-2-32: 
1.0m drop on 38mm of Oak on concrete. 

Mechanical Shock: 

Test per IEC 68-2-27 

Vibration: 

Test per IEC 68-2-6 

Dimensions: 

5.47 x 2.00 x 1.18" (139 x 51 x 30mm) 

Weight: 

180g (6.5oz) 

Polycarbonate Material: 

Jaws:  Polycarbonate with 10% fiberglass charge, 

Red UL 94 V0 

Case: Polycarbonate 920A Gray

Opening Operations - Life: 

> 50,000 

Output: 

Double/reinforced insulated 5 ft (1.5m) lead with 
safety 4mm banana plug  

SAFETY SPECIFICATIONS 

Electrical: 

Double insulation or reinforced insulation between 
the primary or secondary and the outer case of the 
handle conforms to IEC 1010-2-32. 

Dielectric Strength: 

IEC 1010-2-32, Category III, Pollution Degree 2 
5550V, 50/60 Hz between primary, secondary  
and the outer case of the handle 

Electromagnetic Compatibility:

EN 50081-1 Class B 
EN 50082-2 Electrostatic discharge 
   IEC 1000-4-2 
Radiated field IEC 1000-4-3 
Fast transients IEC 1000-4-4 
Magnetic field at 50/60 Hz IEC 1000-4-8 

ORDERING INFORMATION 

AC Current Probe MN307 ................. Cat #2116.23 

Accessories:

Banana plug adapter 
(to non-recessed plug)  ....................... 

Cat #1017.45

E192383

2.56"

 (65 mm)

5.47"

 (139 mm)

.83"

 (21 mm)

Black

Red

.73"

2.00"

 (51 mm)

(18.5 mm)

.1.18"     

(30 mm)

Tactical

Barrier

(keep hands below

this barrier)

MN307

Reviews: