15
STEAM CONNECTION (25)
Position 1.
Connection and extraction
Position 2.
Connection locking
Position 3.
Connection rotation
smooth movement between socket and plug, it is necessary to lubricate the O-rings of the
accessories (shown in the images below) to prevent them from breaking. In the event of
steam leaks between the steam plug and the steam outlet, switch off the machine, unplug
the steam plug and check the O-rings. In case of breakage, reposition a new O-ring (if
necessary, please contact the Technical Assistance Center).
HOW TO EMPTY/CLEAN THE BOILER
•
The emptying/cleaning operation must be carried out periodically according to the
use of the machine, at least once a month. • Disconnect the machine from the mains
and wait until the pressure has dropped to “0” and the boiler is cold. • When the boiler
is cold and the needle of the pressure gauge
14
points to “0”, place a container at the
base of the boiler. Carefully open the drain cock
3
, allowing the water and residues to
escape. Close tap
3
when there is no more water.
AT THE END OF THE WORK TURN OFF ALL THE SWITCHES. IN THE EVENT OF
LONG PERIODS OF INACTIVITY, DISCONNECT THE POWER PLUG, EMPTY THE
BOILER AND STORE THE MACHINE IN A DRY PLACE.