background image

The Aeotec Home Energy Meter can report wattage energy usage or kWh energy usage to a control point 

when requested. If this function is supported by the controller point, the energy consumption will be 

displayed in the user interface of the control point. (The specific Z-Wave commands supporting energy 

monitoring are the Meter Command Class)

Node Information Frame

NI

 The Node Information Frame is the business card of a Z-Wave device. It contains information 

about the device type and the technical capabilities. The inclusion and exclusion of the device is confirmed 

by sending out a Node Information Frame. Beside this it may be needed for certain network operations to 

send out a Node Information Frame.

A single click on the little button on the backside sends a Node Information Frame.

Associations

A

 Z-Wave devices control other Z-Wave devices. The relationship between one device controlling 

another device is called association. In order to control a different device, the controlling device needs to 

maintain a list of devices that will receive controlling commands. These lists are called  association groups 

and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event 

happens all devices stored in the respective association group will receive a common wireless command.

Association Groups:

1 Receiver of all Reports (max. nodes in group: 5)

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can 

adapt the function better to user needs or unlock further enhanced features.

IMPORTANT: Controllers may only allow to configure signed values. In order to set values in the range 128 

… 255 the value sent in the application shall be the desired value minus 256. For example: to set a 

parameter to 200? it may be needed to set a value of 200 minus 256 = minus 56. In case of two byte value 

the same logic applies: Values greater than 32768 may needed to be given as negative values too.

(c) 2012 Z-Wave Europe GmbH, Goldbachstr. 13, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 4 

Summary of Contents for AEO HEM2-100A

Page 1: ...ize a very stable and secure communication Each message is reconfirmed two way communication and every mains powered node can act as a repeater for other nodes meshed network in case the receiver is not in direct wireless range of the transmitter Z Wave differentiates between Controllers and Slaves Slaves are either sensors S transmitting metered or measured data or actuators A capable to execute ...

Page 2: ...ill report that energy use back to your control point in watts or kilowatt hours and in real time So you can see how much electricity you really use and when you use it The main body is anchored using a back mount The device is powered from a normal AC power supply The device has two clamps and reports W and kWH up to 100 Ampere Before Device is installed Please read carefully the enclosed user ma...

Page 3: ... wires protruding from the bottom of the unit To place the Home Energy Meter Slip open the backing plate from the back of your meter Affix the plate to the selected wall space using the provided screws Attach your meter to the backing plate After an electrician connects your Home Energy Meter to your electrical mains you should include the meter into your Z Wave network Behavior within the Z Wave ...

Page 4: ...l a different device the controlling device needs to maintain a list of devices that will receive controlling commands These lists are called association groups and they are always related to certain events e g button pressed sensor triggers In case the event happens all devices stored in the respective association group will receive a common wireless command Association Groups 1 Receiver of all R...

Page 5: ...end Report Watt for clamp 1 Parameter Number 5 Parameter Size 2 The value represents the minimum change in Wattage for a Report to be sent Value Description 0 32000 W Default 50 Minimum Change to send Report Watt for clamp 2 Parameter Number 6 Parameter Size 2 The value represents the minimum change in Wattage for a Report to be sent Value Description 0 32000 W Default 50 Minimum Change to send Re...

Page 6: ...meter Size 1 The value represents the minimum change in Watage Percent for a report to be sent Value Description 0 255 Default 10 Minimum Change to send Report for clamp 3 Parameter Number 11 Parameter Size 1 The value represents the minimum change in Watage Percent for a report to be sent Value Description 0 255 Default 10 Enable disable reporting CRC 16 Encapsulation Command Parameter Number 13 ...

Page 7: ...lamp 2 8192 Meter Report for kWh for clamp 3 Report Type send in Reporting Group 2 Parameter Number 102 Parameter Size 4 Defines the type of report sent for the Reporting Group 2 Value Description 1 Battery Report 2 MultiSensor Report for the whole device 4 Meter Report for Watt for the whole device 8 Meter Report for kWh for the whole device 256 Meter Report for Watt for clamp 1 512 Meter Report ...

Page 8: ... to default Parameter Number 110 Parameter Size 1 Value Description Send Interval for Reporting Group 1 Parameter Number 111 Parameter Size 1 Defines the time interval when the defined report of Reporting Group 1 is sent out Value Description 0 255 Seconds Default 1 Send Interval for Reporting Group 2 Parameter Number 112 Parameter Size 1 Defines the time interval when the defined report of Report...

Page 9: ...ameter Number 254 Parameter Size 2 Value Description Reset Parameter Number 255 Parameter Size 1 Reset configuration set up to default setting Value Description Command Classes Supported Command Classes Multi Channel version 3 Basic version 1 Association version 1 Version version 1 Meter version 3 Configuration version 1 Manufacturer Specific version 2 Technical Data c 2012 Z Wave Europe GmbH Gold...

Page 10: ...inging new Z Wave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to annonces that is is able to communicate Node Information Frame is a special wireless message issued by a Z_Wave device t...

Reviews: