background image

Load will be closed when the Current overrun (US: 15.5A, other country: 16.2A) and the time more than 2 minutes (0=disabled, 1=enabled).

Value

Description

0

Active Overload Protection (Default)

1

Deactivate Overload Protection

Output Load Status (Parameter Number 20, Parameter Size 1)

Configure the output load status after re

power on.

Value

Description

0

last status (Default)

1

always on

2

always off

Notification on Status Change (Parameter Number 80, Parameter Size 1)

Defines the automated status notification of an associated device when status changes (0=nothing, 1=hail CC, 2=basic CC report).

Value

Description

0

nothing (Default)

1

hail

2

basic CC report

Configure the state of red LED (Parameter Number 81, Parameter Size 1)

Value

Description

0

The LED will follow the status (on/off) of its load. (Default)

1

When the state of Switch’s load changed, The LED will follow the status (on/off) of its load, but the red LED will turn off after 5 seconds if there is no any switch action.

Enables/disables parameter 91/92 (Parameter Number 90, Parameter Size 1)

Value

Description

0

Enabled parameter 91/92 (Default)

1

Disabled parameter 91/92

Minimum Change to send Report (Watt) (Parameter Number 91, Parameter Size 2)

The value represents the minimum change in wattage for a Report to be sent .

Value

Description

0 — 32000

The value represents the minimum change in wattage. (Default 25)

Minimum Change to send Report (%) (Parameter Number 92, Parameter Size 1)

The value represents the minimum change in wattage Percent for a report to be sent. (Valid values 0

100)

Value

Description

0 — 100

The value represents the minimum change in wattage Percent. (Default 5)

Set 101

103 to default (Parameter Number 100, Parameter Size 1)

Value

Description

0

set to default (Default)

1

nothing

Report type send in Reporting Group 1 (Parameter Number 101, Parameter Size 4)

Defines the type of report sent for the Reporting Group 1.

Value

Description

2

Multisensor Report

4

Meter Report for Watt

8

Meter Report for kWh (Default)

Report Type send in Reporting Group 2 (Parameter Number 102, Parameter Size 4)

Defines the type of report sent for the Reporting Group 2.