background image

Value

Description

2

Mutlisensor-Report

4

Meter Report for Watt

8

Meter Report for kWh

Report Type send in Reporting Group 3 (Parameter Number 103, Parameter Size 4)

Defines the type of report sent for the Reporting Group 3.

Value

Description

2

Mutlisensor-Report

4

Meter Report for Watt

8

Meter Report for kWh

Set 111

113 to default (Parameter Number 110, Parameter Size 1)

Value

Description

0

Set to default (Default)

1

nothing

Send Interval for Reporting Group 1 (Parameter Number 111, Parameter Size 4)

Defines the time interval when the defined report of Reporting Group 1 is sent out.

Value

Description

0 — 65535

Interval (Default 720)

Send Interval for Reporting Group 2 (Parameter Number 112, Parameter Size 4)

Defines the time interval when the defined report of Reporting Group 2 is sent out.

Value

Description

0 — 65535

Interval (Default 720)

Send Interval for Reporting Group 3 (Parameter Number 113, Parameter Size 4)

Defines the time interval when the defined report of Reporting Group 3 is sent out.

Value

Description

0 — 32000

Interval

Partner ID (Parameter Number 200, Parameter Size 1)

Value

Description

0

Aeon Labs Standard (Default)

1

AT&T

Enable/disable Configuration Locked (Parameter Number 252, Parameter Size 1)

Value

Description

0

Deactivate configurationlock (Default)

1

Activate configurationlock

Command Classes

Supported Command Classes

CRC-16 Encapsulation (version 1)

Z-Wave Plus Information (version 2)

Manufacturer Specific (version 2)

Version (version 2)

Security (version 1)

Binary Switch (version 1)

All Switch (version 1)

Scene Activation (version 1)

Scene Actuator Configuration (version 1)

Meter (version 3)

Association Group Information (version 1)

Reviews: