Value
Description
2
Mutlisensor-Report
4
Meter Report for Watt
8
Meter Report for kWh
Report Type send in Reporting Group 3 (Parameter Number 103, Parameter Size 4)
Defines the type of report sent for the Reporting Group 3.
Value
Description
2
Mutlisensor-Report
4
Meter Report for Watt
8
Meter Report for kWh
Set 111
‐
113 to default (Parameter Number 110, Parameter Size 1)
Value
Description
0
Set to default (Default)
1
nothing
Send Interval for Reporting Group 1 (Parameter Number 111, Parameter Size 4)
Defines the time interval when the defined report of Reporting Group 1 is sent out.
Value
Description
0 — 65535
Interval (Default 720)
Send Interval for Reporting Group 2 (Parameter Number 112, Parameter Size 4)
Defines the time interval when the defined report of Reporting Group 2 is sent out.
Value
Description
0 — 65535
Interval (Default 720)
Send Interval for Reporting Group 3 (Parameter Number 113, Parameter Size 4)
Defines the time interval when the defined report of Reporting Group 3 is sent out.
Value
Description
0 — 32000
Interval
Partner ID (Parameter Number 200, Parameter Size 1)
Value
Description
0
Aeon Labs Standard (Default)
1
AT&T
Enable/disable Configuration Locked (Parameter Number 252, Parameter Size 1)
Value
Description
0
Deactivate configurationlock (Default)
1
Activate configurationlock
Command Classes
Supported Command Classes
CRC-16 Encapsulation (version 1)
Z-Wave Plus Information (version 2)
Manufacturer Specific (version 2)
Version (version 2)
Security (version 1)
Binary Switch (version 1)
All Switch (version 1)
Scene Activation (version 1)
Scene Actuator Configuration (version 1)
Meter (version 3)
Association Group Information (version 1)