background image

Diagram

Micro Double Switch G2

1. Remove the two screws securing the cover plate.

While the Micro Double Smart Energy Switch G2 is powered in 

a 3-wire system, each external switch/button can be toggled to 

initiate pairing into the Z-Wave network. Or the internal button 

can be pushed to initiate pairing into the Z-Wave network if the 

Micro Double Smart Energy Switch G2 was not put into in-wall 

box.

While the Micro Double Smart Energy Switch G2 is powered in 

a 3-wire system, each external switch/button can be toggled 10 

times in quick succession to initiate removing from the Z-Wave 

network. Or the internal button can be pushed to initiate pairing 

into the Z-Wave network if Micro Double Smart Energy Switch 

G2 was not put into in-wall box.

Note

: If the Micro Double Smart Energy Switch G2 was not put into an 

in-wall box, another way to reset Aeotec Micro Double Smart Energy 

Switch G2 is to press and hold the button which is on Micro Double 

Smart Energy Switch G2 for 20 seconds.

1

2

3

AC Power

Load

Neutral

N

L

L1

L2

L

N

L

N

Micro Double Smart Energy Switch  G2

(Generation 2)

(In-Wall Z-Wave Appliance Module w/ Energy Monitor)

Introduction:

IMPORTANT:

The Aeotec Micro Double Smart Energy Switch G2 is

a low-cost Z-Wave appliance module specifically 

used to enable Z-Wave command and control (on/

off) of existing in-wall switches. It can control 2 loads

independently. It can also report immediate  wattage 

consumption  or  kWh energy usage over a period

of time.

The wireless module is powered from the mains 

supply and is a three-wire design which requires 

a  neutral  connection.  In  the  event  of  power 

failure,     non-volatile  memory  retains  all 

programmed  information  relating  to  the  units 

operating status.

It  also  is  a  repeater  in  the  Z-Wave  network.  

Acting  as  a  bridge  for  communication,  it  will 

forward  Z-Wave  command  messages  to  their 

destinations if the originating controller is out of 

range from the destination node. 

By  taking  advantage  of  the  Z-Wave  mesh 

network,  commands  can  be  routed  to  their 

destination  via  intermediary  “listening”  Z-Wave 

products.  Products that are Z-Wave certified can 

be  used  and  communicate  with  other  Z-Wave 

certified devices.

A  licensed  electrician  with  knowledge  and 

understanding  of  electrical  systems  and  electrical 

safety  should  complete  the  electrical  installation 

inside the main circuit box (usually located outside of 

your house).

Z-Wave Network Instructions:

The Aeotec Micro Double Smart Energy Switch G2 must be  

paired (included) into a Z-Wave network before it can receive 

Z-Wave commands to turn on/off and report its energy usage.  

The  Micro  Double  Smart  Energy Switch  G2  can  only 

communicate to devices  within it’s own Z-Wave network.

Note:

 The LED on the Micro Double Smart Energy Switch 

G2 will blink if it is currently not paired into a Z-Wave network.

In-Wall  Electrical Installation Instructions:

Step 1

Dismounting In Wall Box.

Step 2

Step 3

IMPORTANT:

 The electricity to the circuit must be shut off 

during installation for safety and to ensure that wires are not 

short circuited during installation thus causing damage to 

the Micro Module.

Preparing and Connecting Wires

The Aeotec Micro Double Smart Energy Switch G2 must first be  

powered by a 3-wire system in order to operate. The wiring   

diagram is as follows:

Step 4

Mounting In Wall Box.

Step 5

Restore Power

2. Remove the wall switch cover plate.
3. Remove the two screws securing the wall switch to the wall 

    box. Disconnect both wires from the wall switch.

1. Position  all  wires  to  provide  room  for the device.  Place Micro Double 

    Smart Energy Switch G2 inside the wall box towards the back of the box.

2. Position the antenna towards the back of the box, away from all other

    wiring.

3. Reinstall the wall switch to the wall box.

4. Reinstall the cover plate onto the wall box.

Restore power at the circuit breaker or fuse. 

Installation is complete.

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

ON

ON

ON

ON

ON

ON

ON

ON

ON

ON

ON

ON

ON

ON

ON

ON

ON

ON

Cut wire if

neccessary

Strip Gage

(measure bare

here)

0.27”

(7mm)

Adding/Including/Pairing the Micro Double Smart 

Energy Switch G2 into a Z-Wave Network

Note:

 To include the Aeotec Micro Double Smart Energy Switch

G2 with other controllers, please consult the operation manual 

for these controllers on how to include Z-Wave products 

into an existing network. 

Include

Associate

Learn

Remove

1

Press  the  button  labeled  “Include”  on 

the  Aeotec  Minimote  to  begin  the 

Z-Wave inclusion process.

2

 

Troubleshooting: 

If the Aeotec Micro Double Smart Energy Switch G2

was not successfully included into any Z-Wave network, the LED will 

blink continuously slowly continually. If the Aeotec Micro Double Smart Energy 

Switch   G2   was  successfully included  to  a  Z-Wave  network,  the  Status 

Indication LED will either be solid on or off (depending on if the switch

is on or off) . 

Include

Removing/Resetting the Micro Double Smart Energy 

Switch G2 from your Z-Wave Network

Include

Associate

Learn

Remove

1

Press the button labeled “Remove” on 

the Aeotec Minimote to begin the Z-Wave

removal process.

Remove

Note:

 To remove the Aeotec Double Micro Smart Energy Switch   

G2  from  other  controllers,  please  consult  the  operation 

manual  for  these  controllers  on  how  to  remove  Z-Wave 

products from an existing network.

2

 

Troubleshooting: 

If  the Aeotec Micro Double Smart Energy Switch G2 was 

removed from the Z-Wave network, the Status Indication LED will be 

blinking. If the Aeotec Micro Double Smart Energy Switch G2 was not

successfully removed from the Z-Wave network, the Status Indication 

LED will either be solid on or off (depending on if the switch is on or off).

1. Live / hot wire (Black wire). Connect to Live terminal of Micro Double Smart Energy

    Switch G2.

2. Neutral (White wire). Note: If this wire is not present in the box, a neutral wire must 

    be pulled into the box.

3. Load wire. Connect to Load terminal of Micro Double Smart Energy Switch G2.

4. Signal connection: Using three 

    18 AWG copper wires, connect 

    the terminals of the wall switch 

    to Micro Double Smart Energy

    Switch G2 as shown.

5. Side wire connection

1

2

3

   Make sure that the ends of the wires from the 

wall box are straight (cut if neccessary).

  Remove insulation from each wire and the wall 

box as shown.

Note: The "3V Out" terminal should be used only with the Aeon

         Micro Touch.

4

5

1

2

3

4

Reviews: