97
11.7 CHARGING
Connect the charge positive cable to the battery
positive terminal. Connect the charge negative
cable to the battery negative terminal. Using
0. 9A charging current about 5 hours. (Normal
charging) Or using 4A charging current about
1 hour. (Quick charging) Keep flames and spark
away from a battery being charged. Quick
charging should be limited to an emergency;
normal charging is preferred.
11.8 ELECTRIC STARTER
Information
A weak battery may be unable run the starter
motor quickly enough.
If the battery voltage is enough while the engine
is not cranking, the starter motor may be
damaged.
Troubleshooting
Starter motor turns slowly
Weak battery.
Poorly connected starter motor cable.
Faulty starter motor.
Poorly connected battery ground cable.
Starter motor will not turn
Engine stop switch at left or right position.
Gearshift bar is not at neutral position.
Check for a blown fuse near battery.
Make sure that the battery is fully charged and in good condition.